Thank you for purchasing the SSA3 Indoor / Outdoor wire and wireless Siren Strobe alarm. This product will provide 
you with the peace of mind and protection you expect.  
The SSA3 is a combination wire and wireless Siren & Strobe Alarm. Works with traditional wire trigger from a security 
control panel or as a wireless Z-Wave

TM 

enabled alarm device and will sound a loud siren and flash a strobe light 

when an alarm message or alert is received on any Z-Wave

TM 

enabled network.  

The SSA3 unit WILL ALERT you from the home 

security panel

 only if correctly wired to the panel.   

The SSA3 unit WILL ALERT if you have it connected to a Z-Wave network. 
The SSA3 unit can be used in either way (Wire or Wireless) or BOTH at the same time. 
 

For outdoor Use:  
Unit is not recommended to be used in direct exposure to harsh elements, rain, snow, and sun.   

The  SSA3  is  based  on  wireless  (RF)  transmissions.  Any  wireless  transmission  can  be  subject  to  RF 
interference  and,  although  unlikely,  this  interference  may  cause  the  SSA3  to  not  operate  as  intended.    RF 
transmissions  will  be  attenuated  by  tinted  glass,  in  wall  isolation  with  metal  foils,  metal  objects  etc.  Test 
communication to the SSA3 before final placement. Add additional Z-Wave repeater modules to improve  RF 
communication if necessary. Z-Wave is a mesh network; more units, the better is the communication. 
The SSA3 must not be used in life support and/or safety applications.  Information provided in this document 
is for your convenience and may be superseded by updates to either the document or the product.  It is your 
responsibility to ensure that the SSA3 meets with your specifications. 

 

Specifications: 

Power:  

DC Power adapter 9V to 16V/300mA or wire from Security Panel,  

Distance Range:  

 

Max 100ft line of sight in unobstructed environment, 

Product Size (LxWxD): 

Approx 200mm x 10mm x 60mm height, 

Product Weight: 

500g (1 lb) total weight including power adapter, 

Operating Temperature: 

-10ºC (14F) to +70ºC (158F) 

Sound Intensity: 

120dB @10cm; 105dB@1m 

Anti-tamper switch: 

included 

System Requirement:  

Any Z-Wave

TM

 enabled network and controller. 

  Proposed sequence for testing and installation. 

SSA3 is extremely loud! Be careful when power (permanent or 9V backup) is applied.  Suggested sequence 
for testing and installation is: a) hold tamper switch closed, b) connect the 9V battery, c) program SSA3 into 
your Z-Wave controller, d) test RF communication between your Z-Wave controller and the SSA3, e) improve 
RF communication if necessary with adding additional routing Z-Wave devices, f) disconnect the 9V battery, 
g) place bottom side of the siren to the permanent location, h) connect permanent power, 9V battery and 
trigger wires from Security Panel GND and TAMP+   h) test your siren. 

 

Testing the SSA3 

 

After connecting power to the SSA3, you can test the alarm mode after manually exiting the Network Wide Inclusion (NWI) mode by pressing the 
button once or after the unit is included into any Z-Wave

TM

 enabled network.  To test the SSA3, press and hold the button.  The SSA3 will turn on 

and remain on until the button is released.  While the siren is on, it will continually cycle for 1 second off / 4 seconds on for up to 5 minutes or until it 
is turned off.  While the strobe is on, the unit will flash at a rate of once per second.

  

WARNING:

  

THE SIREN IS EXTREMELY LOUD.  WEAR EAR PROTECTION

!        

 

 

Using the SSA3 in a Z-Wave

TM

 Network

 

 

 

 

 

 

The button inside the unit SW1 is used for including or excluding the SSA3 in 
a Z-Wave

TM

 network.  Refer to your controller’s User Manual for details on 

network inclusion, exclusion, and association. 

Summary of Contents for SSA3

Page 1: ...hat the SSA3 meets with your specifications Specifications Power DC Power adapter 9V to 16V 300mA or wire from Security Panel Distance Range Max 100ft line of sight in unobstructed environment Product Size LxWxD Approx 200mm x 10mm x 60mm height Product Weight 500g 1 lb total weight including power adapter Operating Temperature 10ºC 14F to 70ºC 158F Sound Intensity 120dB 10cm 105dB 1m Anti tamper ...

Page 2: ...SSA3 in your network from a remote location such as from another city state or country Other Z Wave TM Information Generic Device Class GENERIC_TYPE_SWITCH_MULTILEVEL Specific Device Class SPECIFIC_TYPE_NOT_USED Manufacturer Specific Command Class Manufacturer ID 0x0084 Product Type ID 0x0313 Product ID Version and Revision may vary Version Command Class Provides Z Wave and application version inf...

Page 3: ...ore often if main power drops out Do not install batteries that appear damaged or unsealed FCC Compliance Statement Statements Contains Transmitter Module FCC ID XCT Z3US This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interferen...

Page 4: ...of the European Union in 2003 This symbol indicates that this product contains electrical and electronic equipment that may include batteries printed circuit boards liquid crystal displays or other components that may be subject to local disposal regulations at your location Please understand those regulations and dispose of the product in a responsible manner LIMITED WARRANTY THE PRODUCT IS PROVI...

Reviews: