FortrezZ FTS05US User Manual Download Page 1

    

 

                   

 

 

 

 
 

 

 
 

USER MANUAL 

Congratulations on your purchase! The FTS05 sensor is a Z-WavePlus

TM 

Security-enabled device that detects water leaks and 

measures temperature.  In case of leak or high/low temperature conditions it will send alerts on your network.  The FTS05 is 
compatible with other Z-Wave

TM

 and Z-WavePlus

TM

 certified products.  The FTS05 sensor comes in two part numbers for each 

geographic region (where ‘yy’ below indicates, for example, US or EU):

 

 

 

FTS05US and FTS05EU 
 
 

Pair together with our Automatic Water Shut-off Valve & Flow Meter for a complete Damage Prevention system! 

 

 

 

 

 

 

 

 

Flow Meter  

Version 1.0 Updated: 07/25/2017 

 

PAIRS GREAT WITH OUR  

WATER SHUT-OFF VALVE  

 

FLOOD & TEMPERATURE SENSOR

 

 

FTS05

 

 

Summary of Contents for FTS05US

Page 1: ...ork The FTS05 is compatible with other Z WaveTM and Z WavePlusTM certified products The FTS05 sensor comes in two part numbers for each geographic region where yy below indicates for example US or EU FTS05US and FTS05EU Pair together with our Automatic Water Shut off Valve Flow Meter for a complete Damage Prevention system Flow Meter Version 1 0 Updated 07 25 2017 PAIRS GREAT WITH OUR WATER SHUT O...

Page 2: ...dates This manual is subject to change without notice It is your responsibility to ensure that the FTS05 functionality meets your needs and specifications WHAT S IN THE BOX Components included in the box 1 FTS05 Sensor 2 4 Small Casing Screws 3 Install Guide 2x AA Batteries Required Not included ASSEMBLE TEST YOUR SENSOR We recommend you test your sensor for its functionality before adding it to y...

Page 3: ...ng Element Note Water must come into contact with this part of the sensor to activate the sensor Be sure to place sensor flat on its bottom surface pictured right with the sensing element in the flood path Note about Concrete or Natural Stone Floors Placing the sensor directly onto a cold surface such as a concrete or natural stone floor may cause false alarms The humidity and out gassing that ris...

Page 4: ...r Z wave Network 1 Check to make sure the sensor isn t already in a network Press the program button and observe LED indicator You may need to first exclude the unit from a network then include it Status LED Indications Number of LED Blinks Meaning Fast Blinks 1 switch pressed continually on while switch is pressed 2 In Network After Battery Replacement or Add Inclusion also after button held whil...

Page 5: ...zing battery life and getting updates for your specific application If you want temperature updates you should only select one of these association groups to send to a particular device Caution More frequent notifications will decrease battery life Association Group Name Max Associations per Group Supported Events Command Classes 1 Lifeline the controller should automatically set up this associati...

Page 6: ...ress and hold the program button for longer than 15 seconds 2 Release the button 3 The LED will flash approx 30 times This can be done while the device is either in or out of a network Caution When this is done in network the device will no longer be in the network and all configurations and associations will be set to default Over the Air OTA Firmware Update mode If running on batteries a firmwar...

Page 7: ...LEVEL COMMAND_CLASS_BASIC for controlling associated nodes when Water and Heat alarms exist Basic commands to the water sensor are ignored COMMAND_CLASS_SENSOR_MULTILEVEL_V9 Temperature value type COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_WAKE_UP COMMAND_CLASS_BATTERY COMMAND_CLASS_NOTIFICATION Notifications are sent for the following types and events Power Management EVENT_INACTIVE 0x00 EVENT_POW...

Page 8: ... there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between th...