![Fortress Technologies ES210 User Manual Download Page 135](http://html.mh-extra.com/html/fortress-technologies/es210/es210_user-manual_2322466135.webp)
Bridge GUI Guide: Security Configuration
120
4.1.4
MSP Re-Key Interval
Fortress Bridges generate new keys at defined intervals,
renegotiating dynamic keys with their Secure Clients whenever
those Clients are logged on. You can specify the re-key
interval, in hours, at values between 1 and 24. The default is 4.
At the default, for example, to decrypt data intercepted over a
12-hour period, a hacker would need to recover three sets of
keys just from the Bridge, quickly enough to employ them
before the next re-key—a highly unlikely possibility. Connecting
devices’ re-keying behaviors would generate additional key
exchanges, and keys from the Bridge alone would not permit
network access.
Every new key negotiation adds network traffic, and the
increased security of shorter re-key intervals should be
balanced against throughput considerations.
4.1.5
Access to the Bridge GUI
In order for the Bridge GUI to be usable,
GUI Access
must be
Enabled
. When
GUI Access
is
Disabled
, the Bridge can be
managed exclusively through the Bridge CLI.
Access to the Bridge GUI is
Enabled
by default.
If you disable the Bridge GUI from within the interface, your
current session will end. You must re-enable the Bridge GUI
from the Bridge CLI before the former will again be accessible
(refer to the
CLI Software Guide
).
NOTE:
The
Bridge’s com-
mand-line interface can
always be accessed via a
direct connection to the
Bridge’s serial
Console
port (refer to the
CLI
Software Guide
).
4.1.6
Secure Shell Access to the Bridge CLI
In order for the Bridge CLI to be accessible via the network,
Secure Shell (SSH®) must be
Enabled
. When
SSH Access
is
Disabled
, you can access the Bridge CLI exclusively through a
direct connection to its
Console
port.
SSH Access
is
Enabled
on the Bridge by default.
4.1.7
Blackout Mode
The
Blackout Mode
setting on the Fortress Bridge globally turns
all chassis LEDs on and off.
When
Blackout Mode
is
Enabled
, none of the Bridge’s LEDs will
illuminate for any reason—except for a single, initial blink
(green) of less than half a second, at the beginning of the boot
process. When
Blackout Mode
is
Disabled
(the default), the LED
indicators function normally.
You can also enable/disable blackout mode through chassis
controls on some Bridge hardware models (refer to the
Hardware Guide
for the Bridge you are configuring) or through
the Bridge CLI (refer to the
CLI Software Guide
).