To replace only the handle (7.M) follow the
instructions given below:
Pull out the cap (7.L), loosen the grub screw (7.I)
and remove the handle (7.M).
DO NOT move the bar of the new cartridge
(7.Q) so as to not compromise the calibration.
Reassemble the new handle (7.M) and lock
it with the grub screw (7.I). Complete the
installation by inserting the cap (7.L).
To replace the cartridge (7.V), remove the lever
(7.C), loosen the grub screw (7.B) and pull out
the handle (7.A). After disassembling the plate
(7.H) screw on the stop cocks (7.S) in clockwise
direction using a screwdriver. Remove the screw
(7.D) and the joint (7.E). Using a wrench,
remove the lock nut (7.U), pull out the cartridge
(7.V) and replace it if necessary. Carefully clean
the support sealing surfaces of the gaskets and
reassemble in reverse order. Tighten the lock
nut (7.U) so as to ensure a proper sealing and
enable a smooth operation of the handle (7.A).
To replace the thermostatic cartridge (7.Q),
remove the lever (7.C), loosen the grub screw
(7.B) and pull out the handle (7.A). After sliding
off the plate (7.H) screw on the stop cocks (7.S)
in clockwise direction using a screwdriver.
To replace the thermostatic cartridge with the
handle (7.T) follow the instructions given below:
remove the grub screw (7.R) and pull out the
thermostatic cartridge with the handle (7.T). Fit
the new assembly (7.T) into the faucet housing
carefully aligning the positioning hole with the
grub screw housing (7.R). Tighten the grub
screw without forcing it so as to not cause
malfunctionings or damages.
To replace only the thermostatic cartridge (7.Q)
follow the instructions given below:
Remove the grub screw (7.R) and pull out the
thermostatic cartridge with the handle (7.T)
from the body. Remove the cap (7.L) from the
assembly, loosen the grub screw (7.I) and slide
off the handle (7.M). Remove the ring (7.N),
the lock nut (7.O) and the peg (7.P) from the
thermostatic cartridge (7.Q).
Install the new thermostatic cartridge (7.Q)
into the faucet housing carefully aligning the
positioning hole with the grub screw housing
(7.R). Tighten the grub screw without forcing it
so as to not cause malfunctioning or damages.
DO NOT move the bar of the new cartridge
Based on its policy of steady development Fortis reserves the right to change the characteristics
of the products without notice and therefore the images and data contained in this catalogue may vary.
(7.Q) so as to not compromise the calibration.
Install the temperature adjustment lock nut
(7.O) as shown and screw on the peg (7.P).
Assemble the handle (7.M) putting the ring
(7.N) in between. Lock it using the grub screw
(7.I) and complete by installing the cap (7.L).
Once completed the replacement, remove the
stop cocks (7.S) turning them in anti-clockwise
direction using a screwdriver. Reassemble the
plate (7.H), fit the handle (7.A) and lock it with
the grub screw (7.B). Complete the assembly
inserting the lever (7.C).
FIG. 08
The figure shows the faucet correctly assembled.
Start the water flow by rotating clockwise or
anti-clockwise handle (8.A) by 90°, adjust the
temperature using handle (8.B).
The thermostatic cartridge is equipped with
a safety anti-scalding retainer set at 100°F
(38°C). For higher temperatures push the
button on the adjustment handle. In case of
hot or cold water pressure failure, the flow will
automatically stop.
MAINTENANCE OF THE SURFACES
Before cleaning, make sure the faucet is cold
(heat wears the surface of the faucet down). Do
not use products containing acids or corrosive
substances. Wipe the faucet daily with a soft
cloth. Do not use steel wool or metal pads,
abrasive sponges or similar products. Right
after cleaning rinse off the detergent residues
with cold water. Damages to the faucets caused
by incorrect treatment are not covered by the
warranty.