background image

Hardware Install Guide for FortiScan

6

http://docs.fortinet.com/

 • 

Document feedback

Mounting the hardware

This section describes mounting FortiScan hardware and supplying power.

Cautions & warnings

Please review the following cautions before installing your FortiScan appliance.

Battery disposal

There is a risk of explosion if the battery on the main board is replaced by an incorrect 
type. Dispose of used batteries according to instructions.

Restricted access location

The FortiScan appliance is intended for installation in a restricted access location. 

Grounding

Ensure the FortiScan appliance is connected and properly grounded to a lightning 
and surge protector. WAN or LAN connections that enter the premises from outside 
the building should be connected through a surge protector.

Shielded Twisted Pair (STP) Ethernet cables should be used whenever possible 
rather than Unshielded Twisted Pair (UTP).

Do not connect or disconnect cables during lightning activity to avoid damage to the 
FortiScan appliance or personal injury.

Rack mounting

Elevated Operating Ambient

 — If installed in a closed or multi-appliance rack 

assembly, the operating ambient temperature of the rack environment may be 
greater than room ambient temperature. Therefore, consideration should be given 

Summary of Contents for FortiScan-1000C

Page 1: ...Hardware Install Guide for FortiScan Donghai Zhao...

Page 2: ...disposal 6 Restricted access location 6 Grounding 6 Rack mounting 6 Environmental specifications 7 Mounting the FortiScan appliance 7 FortiScan 1000C 8 Removing the system from the rack 15 Installing...

Page 3: ...ppliances provide ready to deploy fixes and enforcement actions which can change host configurations to mitigate weak settings and patch applications This frees your time to focus on zero day vulnerab...

Page 4: ...t s examples it would be shown as a non Internet routable IP such as 10 0 0 1 192 168 0 1 or 172 16 0 1 Cautions notes tips This document uses the following guidance and styles for cautions notes and...

Page 5: ...LE Firewall Authentication TITLE HEAD BODY H4 You must authenticate to use this service H4 Hyperlink https support fortinet com Keyboard entry Type a name for the remote VPN peer or client such as Cen...

Page 6: ...d access location Grounding Ensure the FortiScan appliance is connected and properly grounded to a lightning and surge protector WAN or LAN connections that enter the premises from outside the buildin...

Page 7: ...maintained Particular attention should be given to supply connections other than direct connections to the branch circuit e g use of power strips If required to fit into a rack appliance remove the ru...

Page 8: ...nents in a rack never pull more than one component out of the rack on its slide assemblies at one time The weight of more than one extended component could cause the rack to tip over and may result in...

Page 9: ...oms holes of the first U 2 4 Engage the back end of the rail until it fully seats on the vertical rack flange and the second tooth on the latch locks in place Repeat these steps to position and seat t...

Page 10: ...each end piece in the front holes of the vertical rack flanges 1 3 Align each end piece to seat the pegs in the top and bottom holes of the first U 2 4 Engage the back end of the rail until it fully s...

Page 11: ...ssis rail members with the corresponding pins on the system 1 Figure 3 Installing the chassis rail members 2 Slide the chassis rail members towards the back of the system until each one locks into pla...

Page 12: ...rs are locked into the slide rails on both sides Pull the sliding rails out of the rack until they lock into place 1 Figure 4 Installing the system in the rack 2 Align and insert the ends of the chass...

Page 13: ...age automatically as the system is pushed into the rack and are released by pulling up on the latches 2 3 To secure the system for shipment in the rack or for other unstable environments locate the ha...

Page 14: ...lide rail and push the bracket forward until it locks into place Repeat the same process for the CMA attachment bracket marked B Figure 6 Installing the CMA attachment brackets To route the cables 1 B...

Page 15: ...s 2 on the sides of the chassis rail members 1 3 Pull the tabs towards the front of the system to release the chassis rail members from the rails Continue pulling the system until the chassis rail mem...

Page 16: ...tray out of the receiver brackets 2 Note To secure the CMA for shipment in the rack loop the tie wraps around both baskets and tray and cinch them firmly For larger CMAs the tie wraps can be threaded...

Page 17: ...end of the CMA on the innermost bracket of the slide assembly until the latch engages 1 Figure 10 Installing and removing the cable management arm 2 Fit the other latch on the end of the outermost bra...

Page 18: ...e tie wraps provided bundle the cables together as they enter and exit the baskets so they do not interfere with adjacent systems 1 2 With the CMA in the service position route the cable bundle throug...

Page 19: ...e power button optical drive and hard drives The LCD panel and navigation buttons are accessible through the front bezel To remove the front bezel 1 Using the system key unlock the bezel 2 Pull up on...

Page 20: ...re 13 Installing the power cord retention bracket 4 Plug the other end of the power cables into a grounded electrical outlet or a separate power source such as an uninterrupted power supply UPS or a p...

Page 21: ...holes of the first U 4 5 Engage the back end of the rail until it fully seats on the vertical rack flange and the second tooth on the latch locks in place Repeat these steps to position and seat the...

Page 22: ...rail until it fully seats on the vertical rack flange and the first tooth on the latch locks in place Repeat these steps to position and seat the front end piece on the vertical flange 3 5 To remove...

Page 23: ...slots 3 Figure 16 Installing the system on the rack 4 Push the system inward until the front release latch clicks into place Press the slide release lock buttons on both rails and slide the system in...

Page 24: ...To route the cables 1 Locate the inner and outer CMA brackets on the interior sides of both rack flanges 1 Figure 18 Routing the cables 2 Bundle the cables gently pulling them clear of the system con...

Page 25: ...e management arm tray 1 cable management arm 2 nylon cable tie wraps 3 Use the instructions below to install the CMA 1 3 2 Note To secure the CMA for shipment in the rack loop the tie wraps around bot...

Page 26: ...he receiver brackets on the inner edges of the rails and push forward until the tray clicks into place 1 Figure 20 Installing and removing the cable management arm tray 2 To remove the tray squeeze th...

Page 27: ...e CMA away from the CMA tray 1 The CMA can be pulled away from the system and extended away from the tray for access and service 1 2 At the hinged end lift the CMA up and off of the tray to unseat it...

Page 28: ...ets so they do not interfere with adjacent systems 1 2 With the CMA in the service position route the cable bundle through the inner and outer baskets 2 3 Use the pre installed Velcro straps on either...

Page 29: ...e power button optical drive and hard drives The LCD panel and navigation buttons are accessible through the front bezel To remove the front bezel 1 Using the system key unlock the bezel 2 Pull up on...

Page 30: ...the power cables to the system 2 Bend the system power cable into a loop and secure the cable to the bracket using the provided strap Figure 24 Securing the power cord 3 Plug the other end of the powe...

Page 31: ...on conventions 3 E earthing 7 Ethernet 6 exploit 3 F federal desktop core configuration FDCC 3 Fortinet Technical Documentation conventions 3 H Health Insurance Portability and Accountability Act HIPA...

Page 32: ...inet com Document feedback square hole racks 20 storage temperature 7 supply wiring 7 T temperature 6 7 tips 4 troubleshooting 4 U United States government configuration baseline USGCB 3 unshielded tw...

Page 33: ...express or implied except to the extent Fortinet enters a binding written contract signed by Fortinet s General Counsel with a purchaser that expressly warrants that the identified product will perfo...

Reviews: