Deployment

The capacity of the multi-cell system must be high enough to guarantee that subscribers can be reached in high-density
traffic. The capacity of the multi-cell system is determined by the following:

l

Number of connection channels available. Connection channels are used for phone calls and for list access actions
(when the handset accesses the History or Directory).

l

Grade of service (GoS) determines the number of connections that may not be achieved due to the system being at
full capacity. With a grade of service of 5%, it is permissible for 5% of 300 calls (15 connections) not to be
established. This means that only 285 connections have to be achieved.

To calculate the number of connection channels required, use the following formula:

(<Number of calls per hour> – (<Number of calls per hour> x <GoS%>)) x <Average length of call per
hour> / 60 min.

As an example, you set the GoS at 5% and you require 300 calls per hour at an average length of 5 minutes each. The
equation would be: (300 – (300 x 5%)) x 5/60 = 23.75. This means that 24 connection channels would be required, and
you would need 3 base stations.

Since the traffic volume is not normally evenly distributed over the site to be covered, the traffic volume must be
calculated for each area (offices, hotspots, stairwells) to determine the number of base stations that need to be
installed.

Estimating number of base stations based upon area

Estimate the approximate number of base stations according to the total area of expected DECT coverage.

The calculation for this is:

Number of base stations = <size of coverage area (in square meters)> / 800

The suggested distance between two base stations depends on the physical path between the base stations.

The following table lists the recommended distance between two base stations:

Area

Distance between two base stations

Office areas

Up to 40 meters

Office areas with obstacles such as elevator shafts,
stairwells or metal walls

Up to 10 meters

Shop floors

Up to 60 meters

Exhibition halls or production areas without obstacles

Up to 100 meters

Underground garages

Up to 20 meters

As the base stations can interfere with each other, sufficient distance should be maintained between two base stations.
The minimum distance depends on the circumstances. If there are no obstacles between them, the required distance
can be from 5 to 10 meters. If there are obstacles such as absorbent walls or absorbent furniture between them, 1 to 2
meters may be sufficient.

FortiFone FON-D72 User Guide

11

Fortinet Technologies Inc.

Summary of Contents for FortiFone-FON-D72

Page 1: ...FortiFone FON D72 User Guide...

Page 2: ...ort fortinet com FORTINET TRAINING CERTIFICATION PROGRAM https www fortinet com support and training training html NSE INSTITUTE https training fortinet com FORTIGUARD CENTER https fortiguard com END...

Page 3: ...oyment 10 Estimating number of base stations based upon handsets 10 Estimating number of base stations based upon area 11 Calculating base station layout and measurements 12 Base station clusters 12 S...

Page 4: ...f the FortiFone FON D72 User Guide 2020 11 25 Updated Estimating number of base stations based upon handsets on page 10 Removed references to version 6 0 0 The version number is not required for this...

Page 5: ...ne features l Up to 8 concurrent calls per base up to a maximum of 100 l Up to 8 handsets per base up to a maximum of 100 l Supports up to 30 FON D72 B bases increasing the amount of calls handsets an...

Page 6: ...e of the base l Orange the role is DECT Manager l Green the role is Base l Slow flashing orange active calls on the DECT Manager 3 DECT LED Indicates the power status of the base station l Green DECT...

Page 7: ...Introduction Requirements A FON D72 configuration requires the following l 1 x FON D72 M l 1 x FON D72 B l 1 x FON D71 H FortiFone FON D72 User Guide 7 Fortinet Technologies Inc...

Page 8: ...ion l Setting up the phone Mounting the base station The base station can be wall mounted using two screws set 59 mm apart The base station may be mounted upright A sideways B or on the ceiling C The...

Page 9: ...xtensions on FortiVoice 2 On the FON D71 H handsets press the Reg softkey The handsets will display their name and extension number on screen For use as an external extension To configure as an extern...

Page 10: ...stations based upon handsets The following requirements must be considered when estimating how many base stations are needed and deciding where they should be placed l DECT radio coverage of the enti...

Page 11: ...ibuted over the site to be covered the traffic volume must be calculated for each area offices hotspots stairwells to determine the number of base stations that need to be installed Estimating number...

Page 12: ...ract with the base station History and Directory Load Balancing If the current base station is overloaded with active DECT or media connections the DECT connection is set up with a neighboring base st...

Page 13: ...ynchronization loss There can only be one base that is set to sync level 1 Keep this in mind when configuring the FON D72 in FortiVoice Correct Incorrect The multi cell network can be configured in nu...

Page 14: ...f environmental conditions For optimal signal strength it is best to first temporarily put base stations in place and measure the signal transmission The following table gives a general guideline on t...

Page 15: ...ns at corridor intersections like so l In a multi story building we recommend that you install additional base stations in the stairwells l Do not install the base in suspended ceilings cupboards or o...

Page 16: ...different building materials The following table displays the loss of DECT signal through the various materials Building materials Degree of attenuation Metal Very High Concrete walls High Brick wall...

Page 17: ...station D and F For the office room hotspot two additional base stations have been placed in parallel for optimal coverage and channel connections In this example the other hotspot is the After sales...

Page 18: ...lay the following RSSI Received Signal Strength Indication The recommended value is 27 to 85 dBm For guaranteed call quality and interference free handover a reading of 80 dBm To guarantee synchroniza...

Page 19: ...our measurement log The following image presents an example planning drawing The following table presents an example of measurement log results in dBm 100 for the above planning drawing Measuring poin...

Page 20: ...synchronize we recommend that the signal value between the base stations be kept above 85 dBm For this procedure 1 Leave the first level base station at the planned position Take the measuring handset...

Page 21: ...lts display that the signal strength is sufficient for synchronization everywhere Base station F and D can only receive base station E with sufficient quality and base station B C and E can only recei...

Page 22: ...ng dedicated base stations in the stairwells As shown here base station M has been added into the planning drawing in the stairs In this configuration also measure the signal strength within the stair...

Page 23: ...1 On the Extensions page of the FortiVoice interface ensure the MAC address is correctly entered and the Phone Type is FortiFone D72 Save your configuration and reboot the phone 2 If your phone is an...

Page 24: ...inet enters a binding written contract signed by Fortinet s General Counsel with a purchaser that expressly warrants that the identified product will perform according to certain expressly identified...

Reviews: