Connecting the FortiAnalyzer unit
Installing the FortiAnalyzer unit
Connecting the FortiAnalyzer unit
You can install the FortiAnalyzer unit as a free-standing appliance on any stable
surface. You can also mount the FortiAnalyzer-800, FortiAnalyzer-2000 and
FortiAnalyzer-4000/4000A onto a rack unit.
Environmental specifications
• Operating temperature: 41 to 95°F (5 to 35°C)
If you install the FortiAnalyzer unit in a closed or multi-unit rack assembly, the
operating ambient temperature of the rack environment may be greater than
room ambient temperature. Therefore, make sure to install the equipment in an
environment compatible with the manufacturer's maximum rated ambient
temperature.
• Storage temperature: -4 to 176°F (-20 to 80°C)
• Humidity: 10 to 90% non-condensing
Air flow
• For rack installation, make sure that the amount of air flow required for safe
operation of the equipment is not compromised.
• For free-standing installation, make sure that the appliance has at least 1.5 in.
(3.75 cm) of clearance on each side to allow for adequate air flow and cooling.
Mechanical loading
You can mount the FortiAnalyzer-800, FortiAnalyzer-2000 and
FortiAnalyzer-4000/4000A units in a standard 19-inch rack. The FortiAnalyzer-800
requires 1U of vertical space and the FortiAnalyzer-2000 and
FortiAnalyzer-4000/4000A requires 2U of vertical space in the rack.
For rack installation, ensure an even mechanical loading of the FortiAnalyzer-800,
FortiAnalyzer-2000 and FortiAnalyzer-4000/4000A to avoid a hazardous
condition.
Connecting to the network
To connect the FortiAnalyzer unit to the network
1
Place the unit on a stable surface, or in a 19-inch rack unit.
2
Make sure the power of the unit is turned off.
3
Connect the network cable to the LAN or Port 1 interface.
4
Connect the power cable to a power outlet.
5
Turn on the power switch.
Note:
The FortiAnalyzer unit may overload your supply circuit and impact your surge
protection and supply wiring. Use appropriate equipment nameplate ratings to address this
concern.
Make sure that the FortiAnalyzer unit has reliable grounding. Fortinet recommends direct
connections to the branch circuit.
Summary of Contents for FortiAnalyzer-100A
Page 1: ...www fortinet com FortiAnalyzer Version 3 0 MR3 A D M I N I S T R A T I O N G U I D E...
Page 10: ...FortiAnalyzer Version 3 0 MR3 Administration Guide 10 05 30003 0082 20060925 Contents...
Page 88: ...FortiAnalyzer Version 3 0 MR3 Administration Guide 88 05 30003 0082 20060925 Log rolling Logs...
Page 138: ...FortiAnalyzer Version 3 0 MR3 Administration Guide 138 05 30003 0082 20060925 Output Alerts...
Page 161: ...www fortinet com...
Page 162: ...www fortinet com...