72
Calibration
2.8.
Tilt the mixer so that the water flows into the graduated cylinder. Measure the collect-
ed water in milliliters.
2.9.
In the
Actual
menu, enter this measured quantity using the number keys.
2.10. Confirm with
.
2.11.
Date
now shows the current date.
2.12. Repeat the calibration to check your results.
3. Calibrate other
liquid components
using the same method.
Proceed as follows to calibrate powder components without calibration scales:
1. Navigate via
> Calibration
to the
Components
sub-menu.
2. In the
MP
menu, you calibrate the milk substitute.
2.1.
Confirm
MP
by choosing
.
2.2.
Set quantity
shows the amount of milk substitute (MP) to be dispensed by the auto-
matic feeder.
2.3.
Runtime
shows the time in which the automatic feeder should dispense the MP.
2.4.
Date
shows when MP was last calibrated.
2.5.
Tilt the empty mixer forward.
2.6.
Hold the container for the MP under the powder discharge.
2.7.
Confirm
Start?
by choosing
.
2.8.
Confirm
Exit automatic mode?
by choosing
. This message will only be dis-
played if your automatic feeder is still in automatic mode.
Powder will be dispensed.
2.9.
Place the container with the collected MP on the scales.
2.10. In the
Actual
menu, enter the weighed quantity using the number keys.
2.11. Confirm with
.
2.12.
Date
now shows the current date.
2.13. Repeat the calibration to check your results.
3. Calibrate other
powder components
using the same method.
6.2
Calibrating with calibration scales
The automatic feeder determines the actual value using the built-in automatic calibration scales
(additional equipment).
Proceed as follows to calibrate liquid components using the calibration scales:
1. Navigate via
> Calibration
to the
Components
sub-menu.
2. In the
Water
menu, you calibrate water.
2.1.
Confirm
Water
by choosing
.
2.2.
Set qty
shows the quantity of water to be dispensed by the automatic feeder.
2.3.
Runtime
shows the time in which the automatic feeder should dispense the water.