background image

• Generator OK with continuous output 

> 4,000 W (120V) or 10,500 W 

(240V)

• Extension cord: (120V) #12 AWG or 

#10 AWG (240V) or larger. 25’ (8m) 

or shorter recommended

• Always follow local electrical codes

Dedicated Circuit 

240VAC - 50A 

breaker recommended 

or 120VAC - 20A 

outlet, 30A breaker

Connect to Input power

* TIG Torch Sold Separately

4.

6.

Use lift arc technique to initiate a welding 

arc

7.

Adjust amperage per 

material thickness

Connect TIG torch lead 

to gas (100% Argon)

5.

Connect TIG torch and 

ground clamp

3.

ELECTRODE IS ALWAYS ELECTRICALLY 

HOT WHILE IN TIG MODE

• Generator OK with continuous output 

> 4,000 W (120V) or 10,500 W 

(240V)

• Extension cord: (120V) #12 AWG or 

#10 AWG (240V) or larger. 25’ (8m) 

or shorter recommended

• Always follow local electrical codes

Dedicated Circuit 

240VAC - 50A 

breaker 

recommended or 

120VAC - 20A 

outlet, 30A breaker

*Performance may vary by brand

Connect to Input power

Recommended electrodes

4.

Adjust amperage per 

settings chart

5.

Connect electrode 

holder and ground 

clamp according to 

desired polarity

3.

Usually DCEP - Electrode Positive 

QUESTIONS OR TROUBLE? Contact Forney Industries at 1-800-521-6038 

[email protected] • askforney.com • forneyind.com

Read user manual

Select         DC TIG process

2.

1.

Select         STICK process

1.

EN_v1

TIG Torch

Ground 

Clamp

Electrode

Diameter

Inches

MM

AMPS

E6010 

E6011

E6013

E7014

E7018

Amperage

3/32

1/8

5/32
1/16
3/32

1/8

5/32
3/32

1/8

5/32
3/32

1/8

5/32

2,4
3,2
4,0
1,6
2,4
3,2
4,0
2,4
3,2
4,0
2,4
3,2
4,0

30-75

35-125
80-160

10-50
40-90

50-130
90-180

40-90

60-130
90-180
50-80
80-160
90-180

Electrode Holder

QUICK START GUIDE

 180 ST+ WELDER 

(NOT RECOMMENDED FOR ALUMINUM)

ITEM# 321

TIG WELDING SET-UP

STICK WELDING SET-UP

2.

Pulse Recommendations

3.5-4.2

50-55%

>5

>50%

2-2.4

40-45%

5.5-6.5

50-90%

Hz

% On

Reviews: