Troubleshooting and Repair |
27
error
cause
solution
Parts are
undercured or do
not have desired
mechanical
properties.
Expired resin
Part was washed but not
fully dried before post-
curing
Check the expected lifetime of the resin used for
the print.
Fully dry all solvent off of parts before post-curing.
Post-cured parts
have tacky or
sticky surfaces.
Part was not washed
before post-curing
Part was washed but not
fully dried before post-curing
Wash liquid resin off of printed parts before post-
curing.
Fully dry all solvent off of parts before post-curing.
7.3
Disassembly and Repair
All steps that involve opening the Form Cure and/or investigating internal
components should be done by skilled persons under the guidance of Formlabs or a
certified service provider.
Contact Formlabs or a certified service provider to receive repair instructions and authorization.
The following tools, equipment, and materials are needed for reparation tasks:
task
required supplies
cause
Replacing the
display assembly
2.5 mm hex wrench,
replacement part(s)
The Form Cure display or knob has
stopped functioning.
Replacing the motor
assembly
2.0 mm hex wrench,
2.5 mm hex wrench,
replacement part(s)
The turntable has stopped functioning or
behaves erratically.
Reseating the
ribbon cable
2.5 mm hex wrench
The Form Cure display or knob has
stopped functioning.
NOTICE