INSTALLATION INSTRUCTIONS
Electrical connection (Model 46SVBA)
Connect power to the press after reading all electrical notices and warnings.
The machine is
to be permanently wired to 208-230/460volt 3PH., 15amp circuit, in accordance with
National Electric Code. (For Models 46SVBA-120 & 46SVBA-230, The machine is to
permanently wire to 120/230volt 1PH., 15amp circuit.)
A disconnect switch must be located within operators access in accordance with the
National Electric Code. A breaker installed in a breaker panel is not considered an
acceptable disconnect.
CAUTION
AN ELECTRICAL LOCK-OUT DEVICE SHOULD BE USED ON THE POWER SOURCE
WHEN SERVICING THE MACHINE.
NOTICE
ALL ELECTRICAL WIRING AND CONNECTIONS MUST BE MADE IN COMPLIANCE
WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE AND LOCAL
CODES AND ORDINANCES.
NOTICE
IF AT ANY TIME YOU HAVE QUESTIONS OR FIND SOMETHING THAT IS NOT
OPERATING PROPERLY, YOU MAY CONTACT A FORENTA FACTORY SERVICE
TECHNICIAN: PHONE (423)586-5370, FAX (423)586-3470.
Manual Motor Starter
Blower On/Off Switch
Located in Disconnect Switch Box.
Located in On/Off Switch Box.
(For Models 46SVBA-120 & 46SVBA-230)
Note: Check Blower Motor for
proper rotation after
connecting power.