Espree Shower Mixer

EP300

Congratulations on your purchase of this high quality product from Foreno Tapware. 
Please read the following before installation and retain (along with your receipt) for future reference.

TECHNICAL SPECIFICATIONS

Suitable for All Pressures

Minimum Pressure = 35kPa
Maximum operating Pressure = 500kPa
Maximum operating Temperature = 65 deg. Celsius

For domestic use only.

CONFIGURATION

Mains Pressure systems  Prior to installation, remove the valve inserts from both inlets.
Unequal Low systems  Install as supplied. 

Equal Low systems 

Important note: Only slide showers that are equipped with a large internal bore hose and open flow single 

function handset will work effectively with this shower mixer. We recommend this mixer be used with an  

Espree Slide Shower (EF04 or FSL5) for optimum performance.  If the cold pressure exceeds 500kPa, or the  

pressure difference is greater than 10/1 ratio (i.e. 400kPa cold and 35kPa hot), we recommend installing 

the  needle valve (

not 

supplied) preferably directly to the cold water feed port on the shower mixer or 

alternatively  anywhere on the cold feedline pipe.

Prior to installation, remove the valve inserts from both inlets.

INSTALLATION

Installation must comply with Section 5.4 of AS/NZS 3500 Standard with regard to Isolating stop cock use. Shower 
mixers must be water tested with the outlet open, to prevent damage to cartridge seals; due to back pressure.

All pipe work must be flushed prior to the installation of this mixer, accessible inline filters must be installed in the 
pipework for both the hot and cold inlet supply to prevent particles from damaging the ceramic cartridge.  

Back Flow Prevention: Where back flow prevention is required, install our Back Flow Prevention Valve at the supply 
elbow hose connection of the handpiece.

Any water seepage ex- the cartridge cavity opening can be stopped by retightening the large brass retaining nut.