Battery Part Numbers and Usage
Size
Quantity
Type
Battery Part Number
Single Battery FWD (without Start-Stop)^
H7
1
750 CCA (80Ah @20 hour rate) Standard
Flooded Battery
GK2T-10655-D*
Single Battery FWD (without Start-Stop)^^
H7
1
710 CCA (75Ah @20 hour rate) Enhanced
Flooded Battery
GK2T-10655-E*
Single Battery FWD (with Start-Stop)
H7
1
800 CCA (80Ah @ 20 hour rate)
Absorbent Glass Mat Battery
DV6T-10655-B*
Single Battery RWD (with/without Start-Stop)
H7
1
800 CCA (80Ah @ 20 hour rate)
Absorbent Glass Mat Battery
DV6T-10655-B*
Twin Battery (without Start-Stop)^
H7
2
750 CCA (80Ah @20 hour rate) Standard
Flooded Battery
GK2T-10655-D*
Twin Battery (without Start-Stop)^^
H7
2
710 CCA (75Ah @20 hour rate) Enhanced
Flooded Battery
GK2T-10655-E*
Twin Battery (with Start-Stop)
H7
2
800 CCA (80Ah @ 20 hour rate)
Absorbent Glass Mat Battery
DV6T-10655-B*
High Performance Deep Cycle AGM Batteries (OW5)
H8
2
850 CCA (95Ah @ 20 hour rate) Absorbent
Glass Mat Battery
8C1V-10655-A*
^ 2 year warranty territories, ^^3 year warranty territories
4.4.3 Battery Rules
•
Batteries in parallel must be of the same type
and capacity and listed in the Ford battery
table.
•
Third party batteries and loads are to be
isolated from the standard Ford system at key
off.
•
For external charging of batteries ensure that
the maximum voltage of 15.2V is not exceeded.
Normal proprietary charging equipment should
operate below this voltage.
NOTE:
Charge balance calculations are required
when adding additional systems taking into
account alternator size and battery capacity. On
battery choice a number of factors are important:
Important Factors for Battery Choice
•
Battery specification capability in ampere hours
for continuously loading until empty. For
example: an 95Ah fully charged battery can
supply 4.75 Ampere over a 20 hour period at 20
degrees centigrade until it is fully discharged.
•
The Cold Crank Ampere (CCA) rating is the
maximum rating for cold start requirements.
•
For deep cycling and micro cycling requirements
(engine off loads) the deep cycle battery
system (OW5) is recommended.
Extra batteries added to the power supply should
be connected as shown at the end of this section.
FORD
TRANSIT
2016.75
Date of Publication: 03/2018
EU
4 El
ec
tric
al
114