303-06-209
Starting System
303-06-209
DIAGNOSIS AND TESTING (
CONTINUED
)
E1017 EN
09/2001 2002 Bantam
CONDITIONS
DETAILS/RESULTS/ACTIONS
B2: CHECK THE SUPPLY TO STARTER
1
.
2
Measure the voltage between the starter
terminal B, circuit 30 (RD) and ground.
• Is the voltage greater than 12.5 volts?
Yes
GO TO
B3
No
REPAIR circuit 30 (RD). TEST the system
for normal operation.
B3: CHECK THE STARTER GROUND CIRCUIT
1
Measure the resistance between the starter
motor casing and negative (-) battery terminal.
• Is the resistance less than 5 ohms?
Yes
INSTALL a new starter motor. TEST the
system for normal operation.
No
CLEAN and REPAIR grounds as required.
TEST the system for normal operation.
PINPOINT TEST C: UNUSUAL STARTER MOTOR NOISE
CONDITIONS
DETAILS/RESULTS/ACTIONS
C1: CHECK THE STARTER MOUNTING
1
Check the starter and mounting brackets for
correct alignment.
• Is the starter mounted correctly?
Yes
No
INSTALL the starter motor.
Refer to the procedure in this section.
TEST the system for normal operation.