PINPOINT TEST N: AN INDICATOR IS INOPERATIVE/ALWAYS ON — HIGH BEAM
No
INSTALL a new generator; REFER to
Section 414-02
. CLEAR the DTCs. REPEAT the self-test.
M6
CHECK CIRCUIT 904 (LG/RD) FOR SHORT TO GROUND
Measure the resistance between generator C154, Circuit 904 (LG/RD), harness side and ground.
Is the resistance greater than 10,000 ohms?
Yes
INSTALL a new instrument cluster; REFER to
Instrument Cluster
. CLEAR the DTCs. REPEAT the self-test.
No
REPAIR the circuit. CLEAR the DTCs. REPEAT the self-test.
CONDITIONS
DETAILS/RESULTS/ACTIONS
N1
CHECK THE HIGH BEAM LAMP OPERATION
Operate the high beams.
Do the high beams operate correctly?
Yes
GO to
N2
.
No
REFER to
Section 417-01
.
N2
CHECK CIRCUIT 932 (GY/WH) AND CIRCUIT 12 (LG/BK) FOR AN OPEN
Instrument Cluster C251
Measure the voltage between instrument cluster C251 Pin 2, Circuit 12 (LG/BK), harness side and ground,
while turning the high beams on and off.
Is the voltage 0 volts with the high beams off and greater than 10 volts with the high beams on?
Yes
INSTALL a new instrument cluster; REFER to
Instrument Cluster
. CLEAR the DTCs. REPEAT the self-test.
Page 27 of 32
1999 Mustang Workshop Manual
1/18/2013
http://www.fordtechservice.dealerconnection.com/pubs/content/~WSXB/~MUS~LEN/20/...