SSC6100
Spreader Control
Calibration Manual
Firmware Version 0.57
Page 1: ...SSC6100 Spreader Control Calibration Manual Firmware Version 0 57...
Page 2: ...rials 10 Direct Materials 11 Dust Control Materials 12 Herbicide Materials 13 Truck Tow Plow 13 Inputs 20 Outputs 21 Event Logging 23 Alarms 24 Systems Management 28 Auto Calibration 32 AutoCalibratio...
Page 3: ...t rate Twist Right Increase the spinner set rate Pushbutton Blast Gray Nav Stick Twist Left Decrease digit by 1 Select previous calibration value Twist Right Increase digit by 1 Select next calibratio...
Page 4: ...al 2 Input Action Function Soft Switches 8 Individual Pushbuttons Correspond to the 8 functions shown in the soft switch panes on the lower left portion of the screen Shapes on each button allow match...
Page 5: ...ess Code before it will appear To enter Calibration 1 Move the Operator Interface s Gray Navigation Joystick or Nav Stick left or right until the MENU soft switch pane is displayed 2 Press the CALIBRA...
Page 6: ...broken up into two categories Fleet Wide Settings and Vehicle Specific Settings The Calibration Menu uses a NeverLost menu system to ensure that navigating the settings is easy and quick The Calibrati...
Page 7: ...abled or disabled Sim Speed Shows the SimSpeed data item and the SimSpeed soft switches in the UTIL2 soft switch pane and allow the user to simulate a ground speed without having to physically move th...
Page 8: ...the Nav Stick down function Trigger Allows a custom configurable trigger signal to bring up the camera See your FORCE America representative for options to setup these custom trigger options Triggered...
Page 9: ...threshold values Aux Power Ramp Time Sets how quickly the Aux Power output will ramp up to the set speed Protect Current Data Enables a password screen when clearing Current Data from the Data menu T...
Page 10: ...er Jump Start Speed Stabilizes the spreader outputs at low ground speeds by simulating an artificially higher than actual ground speed until the truck is moving fast enough At speeds above zero the sy...
Page 11: ...losed Loop or Open Loop Mode Materials Enabled Sets how many materials will be available to the user Materials Settings for each of the enabled granular materials Material 1 Material 2 Material 3 etc...
Page 12: ...d to verify the calibration of each material Loop Mode Sets the control output to either Closed Loop Open Loop On Off or Manual operation Materials Enabled Sets how many Prewet materials will be avail...
Page 13: ...Verify softswitch in the Material menu which runs a step by step wizard that can be used to verify the calibration of each material Blast Mode Sets Blast to operate for either a set Time or a set Dist...
Page 14: ...Manual soft switch on the DUST softswitch pane Unload Mode Enables unload mode in the Unload menu AutoVerify Mode Enables the AutoVerify softswitch in the Material menu which runs a step by step wizar...
Page 15: ...Right Boom Width Sets the actual width of each control boom This is used in calculation of the material application rate Materials Settings related to the herbicide material Material 1 Settings avail...
Page 16: ...y calibrating the valve drive Min and Max settings The actual number of outputs and the specific names for each of the outputs is dependent on how your system is configured The process of calibrating...
Page 17: ...anular Materials Materials menu section Calib Gate Height Truck only Sets the gate height that is used when calibrating a given material If this value is changed it will require re calibrating of the...
Page 18: ...educe it until the function begins to slow down then raise it back up until it just reaches full speed Actuator Min Sets the minimum valid voltage for the spinner position sensor Only visible if the s...
Page 19: ...in closed loop mode Decrease this value to stabilize a hunting system or increase this value to speed up a sluggish system Material Countdown Sets up the material countdown functions that show the am...
Page 20: ...nning at maximum duty cycle Closed Loop Gain Adjusts the responsiveness of the system in closed loop mode Decrease this value to stabilize a hunting system or increase this value to speed up a sluggis...
Page 21: ...ere the function is moving slowly and then reduce it until it just comes to a stop Max DC Start with a high value and slowly reduce it until the function begins to slow down then raise it back up unti...
Page 22: ...performance and accuracy by telling the system what the highest RPM the function can achieve when running at maximum duty cycle Closed Loop Gain Adjusts the responsiveness of the system in closed loop...
Page 23: ...table Power Float pressure using the FLOAT softswitches CommandAll Single Contains settings specific to a CommandAll Single Joystick Interlock Time Adjusts how long the interlock will remain active af...
Page 24: ...efined in the hardware configuration file and allows access to the Min Max settings for each one Min DC Provides an adjustment to cause the function to come to a smooth stop at the same time the joyst...
Page 25: ...of repeated events based on a granular displacement interval Gran Displacement Sets the amount of granular material dispensed between Granular Displacement based events Prewet Displacement Enables the...
Page 26: ...ts the audible alarm level that occurs when the Driver ID login warning becomes active High Filter Bypass Contains settings unique to the High Filter Bypass warning Alarm Sets the audible alarm level...
Page 27: ...ecomes active Range Alarm Sets the audible alarm level that occurs when the Auger Conveyor Range Error becomes active Feedback Alarm Sets the audible alarm level that occurs when the Auger Conveyor Fe...
Page 28: ...at occurs when the Anti Ice Low Liquid Error becomes active Range Alarm Sets the audible alarm level that occurs when the Direct Range Error becomes active Feedback Alarm Sets the audible alarm level...
Page 29: ...ck Alarm Sets the audible alarm level that occurs when the Herbicide Feedback Error becomes active Unload Alarm Sets the audible alarm level that occurs when the Herbicide Unload becomes active Spinne...
Page 30: ...h drive Insert a USB flash drive to activate the menu Clear OTA Calib File Clears the CONFIG file that was received OTA Export All Settings USB Exports all the configuration settings to a USB flash dr...
Page 31: ...SSC6100 CAN Ultra Calibration Manual 29 Shutdown Provides the ability to manually restart the spreader control Restart Now Restarts system without having to cycle the dashkey power on the truck...
Page 32: ...drive to activate the menu Hardware Config Provides methods of managing the hardware configuration settings that determine the capabilities of the system Import HW Config File Allows the import of a n...
Page 33: ...he operator interface System Modules MPJC CommandAll 20 Port 10 Port DLA IM04 Displays the current version for each of the connected modules as defined in the Hardware Config file Modem Type SN 000000...
Page 34: ...measure the axle pulses value STEP 5 Upon completing the wizard the measured axle pulses value will be displayed STEP 6 The Auto Call wizard will detect and offer suggestions to remedy any issues tha...
Page 35: ...applicable 2 Set the associated liquid Feedback Sensor pulses per revolution 3 Adjust the liquid output s Minimum and Maximum Duty Cycle settings 4 If using Auger exhaust prewet mode it is recommended...
Page 36: ...es a means of normalizing the joystick To Normalize a Joystick STEP 1 Enter the Calibration Menu and navigate into the Joysticks submenu located in the Outputs menu STEP 2 Press the NORMALIZE JOYSTICK...
Page 37: ...sabled Vehicle Specific Event Logging Serial Disabled Fleet Wide Event Logging OTA Disabled Fleet Wide Driver ID Disabled Fleet Wide Momentary Spreading Disabled Fleet Wide Dual Camera Mode Disabled V...
Page 38: ...e Disabled Fleet Wide AutoVerify Mode Enabled Fleet Wide Blast Mode Time Fleet Wide Blast Time 10 seconds Fleet Wide Blast Distance 250 FT Fleet Wide Skip Mode Disabled Fleet Wide Skip On Distance 250...
Page 39: ...on at 20F 100 Fleet Wide Compensation at 22F 100 Fleet Wide Compensation at 24F 100 Fleet Wide Compensation at 26F 100 Fleet Wide Compensation at 28F 100 Fleet Wide Compensation at 30F 100 Fleet Wide...
Page 40: ...leet Wide Spray Bar Set Rate 4 35 gal mi Fleet Wide Spray Bar Set Rate 5 40 gal mi Fleet Wide Spray Bar Set Rate 6 45 gal mi Fleet Wide Spray Bar Set Rate 7 50 gal mi Fleet Wide Spray Bar Set Rate 8 5...
Page 41: ...fy Mode Enabled Fleet Wide Blast Mode Time Fleet Wide Blast Time 10 seconds Fleet Wide Blast Distance 250 FT Fleet Wide Loop Mode Closed Fleet Wide Materials Enabled 1 Fleet Wide Material Name DIR1 Fl...
Page 42: ...d2 Fleet Wide Set Rate 6 0 35 gal yd2 Fleet Wide Set Rate 7 0 40 gal yd2 Fleet Wide Set Rate 8 0 45 gal yd2 Fleet Wide Set Rate 9 0 50 gal yd2 Fleet Wide Set Rate 10 0 55 gal yd2 Fleet Wide HERBICIDE...
Page 43: ...ic Maximum Duty Cycle Reverse Outputs 75 Vehicle Specific Maximum Reverse RPM 100 Vehicle Specific Minimum Duty Cycle Cross 1 Outputs 20 Vehicle Specific Maximum Duty Cycle Cross 1 Outputs 75 Vehicle...
Page 44: ...uator Min 0 4 Fleet Wide Actuator Max 4 6 Fleet Wide Five Second Run On Disabled Fleet Wide Spinner Skip Disabled Fleet Wide TRUCK PREWET Drive Type Standard Fleet Wide Pulses per Revolution 12 Fleet...
Page 45: ...3 20 oz rev Vehicle Specific TRUCK HERBICIDE Pulses Per Revolution 10 Fleet Wide Minimum Duty Cycle 20 Vehicle Specific Maximum Duty Cycle 75 Vehicle Specific Maximum RPM 1500 Vehicle Specific Closed...
Page 46: ...icle Specific TOW PLOW DIRECT LIQUID Pulses Per Revolution 10 Fleet Wide Minimum Duty Cycle 20 Vehicle Specific Maximum Duty Cycle 75 Vehicle Specific Maximum RPM 1500 Vehicle Specific Closed Loop Gai...
Page 47: ...econds Fleet Wide Distance Disabled Fleet Wide Distance 2000 feet Fleet Wide Gran Displacement Disabled Fleet Wide Gran Displacement 2000 lbs Fleet Wide Prewet Displacement Disabled Fleet Wide Prewet...
Page 48: ...quid Alarm Single Beep Fleet Wide Range Alarm Solid Tone Fleet Wide Feedback Alarm Solid Tone Fleet Wide Unload Alarm Off Fleet Wide ALARMS DIRECT Low Liquid Action Warn Disable Fleet Wide Direct Low...
Page 49: ...e Feedback Alarm Solid Tone Fleet Wide Unload Alarm Off Fleet Wide ALARMS SPINNER Range Alarm Solid Tone Fleet Wide Feedback Alarm Solid Tone Fleet Wide ALARMS HARDWARE CONFIG WARNINGS HW Config Warni...
Page 50: ...Measurement Units English Enabled Options Sim Speed Disabled Distance Measure Disabled Aux Power Disabled Event Logging Serial Disabled Event Logging OTA Disabled Driver ID Disabled Momentary Spreadi...
Page 51: ...Document No M0136 F Released 09 28 2021 Copyright 2021 FORCE America Inc...