SPECIFICATIONS
Dimensions:
120mm(L) x 42mm(W) x 53.3mm(H)
Weight:
64 g
Battery:
CR2032 3V lithium battery
Displayed Temperature Range:
89.6°F to 109.4°F (32°C to
43°C)
Display Resolution:
0.1°F/0.1°C
Accuracy:
Meet the accuracy requirement specified in ASTM
E1965-98
±0.4°F (±0.2°C) for the range of 96.8°F to 102.2°F
(36.0°C to 39.0°C)
±0.5°F (±0.3°C ) for the range of < 96.8°F (36.0°C) or >
102.2°F (39.0°C)
Temperature Unit:
°F
Operating Temperature Range:
50°F to 104°F (10°C to
40°C)
Operating Humidity:
95% RH or less
Storage Temperature Range:
-4°F to 140°F (-20°C to
60°C)
Storage Humidity:
95% RH or less
Memory Capacity:
10 measurements
The specifications may be changed without prior notice.
TROUBLESHOOTING
All error messages below would be shown together with a red
backlight. Please follow “what to do” to resolve problems. If
the problem still exists, please call your local dealer for help.
What It Means
What To Do
Appear when
environmental
temperature is below
or above system
operation range.
Battery is low.
Thermometer errors.
Appears when the
battery can’t provide
enough power for a
test.
Put the thermometer
under operating
temperature range of
50°F to 104°F (10°C
to 40°C).
Replace the battery with
a new one immediately.
If the problem persists,
please contact your
dealer.
Replace the old battery
with a new one
immediately.
Message
RECALLING THE MEMORY
1
The thermometer comes with one CR2032 3V lithium
battery. Replace it when “ ” appears. Please follow the
steps for battery replacement.
1.
Remove the battery cover.
2.
Place the new battery in the battery compartment and
press it in until the battery are secured.
3.
Reattach the battery cover.
NOTE:
●
Although the thermometer works when “ ” appears, we
still recommend that you change the battery to obtain an
accurate result.
●
Remove the battery if stored for a long period of time.
●
The battery should be kept out of children. If they are
swallowed, promptly see a doctor for help.
●
Properly dispose of the battery.
REPLACING THE BATTERY
1
3
2
CR2032
IR18
EAR THERMOMETER
Operating Instructions
311-1118300-005
ver 1.0 2016/03
Distributed by ForaCare
ForaCare, Inc.
893 Patriot Dr., Suite D, Moorpark, CA 93021 USA
Products made in Taiwan
Toll Free: 1-888-307-8188
(7:00 am - 6:00 pm PST, Mon.-Fri.)
For assistance outside of these hours,
please contact your healthcare professional.
www.foracare.com
Read instructions before use.
Your thermometer stores the last 10 readings in the
memory.
1.
Be sure the thermometer is OFF before recalling the
memory.
2. Press the On/Memory button to turn on the
thermometer.
3.
Each time you press the On/Memory button, a result will
be displayed in the order of dates (latest result shown first),
together with “ ” and a number (from 1 to 10). When the
memory is full, the oldest result is deleted as the new one is
added. When the last record is displayed in the LCD, press
On/Memory button again to return to the first one.
4. Exit the memory.
Press and hold On/Memory button
again, and then the LCD will show “ OFF ” to exit memory.
NOTE:
● The device will automatically turn off if left without
pressing any button within 30 seconds.
● When using the thermometer for the first time, the first
memory result will display “---”. It indicates that there are
no test results in memory.
persons with compromised immune systems, persons taking
antibiotics, steroids or antipyretics (aspirin, ibuprofen,
acetaminophen), or persons with certain chronic illnesses.
Please consult your physician when you feel ill even if you
do not have a fever.
*Chamberlain, J. M. Terndrup, T. E., New Light on
Thermometer Readings, Contemporary Pediatrics, March
1994.
●
The probe is not waterproof. Please wipe it with a clean
and dry cotton swab.
●
The body of the thermometer is not water-resistant.
Never put the thermometer under a running tap or
submerge it into water. Use a soft and dry cloth to clean
it. Do not use abrasive cleaners.
●
Store the thermometer in a cool and dry location that is
free from dust and away from direct sunlight.
●
Keep the probe clean, as build-up of earwax and grease
may affect the measurement.
CARE & CLEANING
Normal Temperature Range
*
95.9°F to 99.5°F (35.5°C to 37.5°C)
94.5°F to 99.1°F (34.7°C to 37.3°C)
97.9°F to 100.4°F (36.6°C to 38.0°C)
96.4°F to 100.4°F (35.8°C to 38.0°C)
Body Site
Oral
Axillary (underarm)
Rectal
Ear
ABOUT NORMAL BODY TEMPERATURE & FEVER
Body temperature can vary from person to person. It also
varies on different parts of the body and time of day. The
following table shows the statistics of normal ranges from
different body parts. Please keep in mind that temperatures
measured from different parts, even at the same time,
should not be directly compared.
Fever indicates that the body temperature is higher than
normal. This symptom may be caused by infection,
overdressing or immunization. Some people may not
experience fever even when they are ill. These include, but
are not limited to, infants younger than 3 months old,
12
13