10-2. Alarm Tab
Clicking an Alarm tab opens a window on the web browser as shown below.
Clicking Refresh allows you to update the window contents.
Item
Function(Default)
Description
Alarm 1
None
Assigns a function for each alarm terminal.
A function is selected from the list below.
Polarity enables you to select alarm output polarity.
Polarity is positive by default.
Alarm 2
Alarm 3
Alarm 4
Alarm 5
Alarm 6
* Refer to Sec. 4-10. "Alarm
Connector” for terminal number details on Alarm 1 to 6.
Function
None
No function is set.
Unit All Alarm
Alarm signal output if one of failures listed below occurs:
Abnormal DC output from power supply unit 1 or 2.
Stopped FAN 1, 2, or 3
High temperature
Front panel open
Power Unit1/2 Alarm
Alarm signal output: Indicates abnormal DC output from Power
Supply unit 1 or 2.
Power Unit1 Alarm
Alarm signal output: Indicates abnormal DC output from Power
Supply unit 1.
Power Unit2 Alarm
Alarm signal output: Indicates abnormal DC output from Power
Supply unit 2.
FAN 1 / 2 / 3 Alarm
Alarm signal output: Indicates stopped FAN 1, 2 or 3.
FAN 1 Alarm
Alarm signal output: Indicates stopped FAN 1.
FAN 2 Alarm
Alarm signal output: Indicates stopped FAN 2.
FAN 3 Alarm
Alarm signal output: Indicates stopped FAN 3.
Temperature Alarm
Alarm signal output: High Temperature indication.
Front Panel Open Alarm
Alarm signal output: Indicates front panel open longer than 5
minutes.