1. Installing the AC Cord Retaining Clip
Secure the AC cord with the supplied ladder strap/retaining clip assembly to prevent accidental disconnection from the USF-212S.
Apply before mounting on the rack.
1) Wrap the retaining clip around the AC cord. (with the anchor of the ladder strap toward the unit.)
2) Insert the anchor into the hole next to the AC IN socket.
3) Lightly fasten the clip around the AC cord.
4) Plug in the power cord.
5) Slide the clip on the ladder strap toward the plug.
6) Fasten the clip tightly.
7) Gently pull on the AC cord to ensure it is secured.
2. Opening the Front Panel
The Front panel may be difficult to open if the USF frame is placed on a desk, and may be damaged the front panel if it is forced
to open. Perform the following steps after setting the frame in a rack.
An OPEN alarm sounds intermittently, every 30 seconds, when the front panel is opened. After 5 minutes, the alarm will sound
continuously until the front panel is closed. In case the power is on, complete the procedure in a short period of time
3. Front Interior
The slot configuration as shown below is revealed when the front panel is removed.
No.
Slot Type
Description
(1)
Power Supply 1 slot
Dedicated power unit is installed in this slot as standard. Power is supplied when the
switch is turned on.
(2)
Power Supply 2 slot
Slot for redundant power supply USF-105PS. Redundant operation available when
optional USF-212PS is installed. A blank panel will otherwise cover the slot.
(3)
Control module slot
Network module is installed in this slot. Enables you to monitor power supply and fan
states via SNMP from back port LAN 1/LAN A and alarm output via GPI. Distributes
reference signal to each module.
(4)
USF module slot
Dedicated USF module slots. (Front USF modules)
For details on module operation, refer to the respective operation manuals.
4. USF Module Installation
USF Modules can be installed into any free slot. If multiple free slots exist, do not install modules side-by-side but leave slots open to
prevent overheating and facilitate signal connection from the rear panel.
The procedure for installing the USF module in Slot 1 is described below as an example.
Installing a USF Rear Module
Installing a USF Front Module
Make sure to install the front module after installing the rear module.
1) SLOT 1 is the top slot in the right block of the front panel. (Refer to Step 3.
“Front Interior.”)
2) Set the module on the guide rail and carefully insert the module slowly.
3) Push the handle until the front module clicks into the connectors.
USF-105S
Setup Guide
USF-105S Packing List
:
USF-105S (1 unit)
AC Cable (1 set, including AC Cord Retaining Clip)
CD-ROM (1)
2)
4)
3)
5)
6)
3G/HD/SD SDI IN
USF-1043FS
1
2
1
2
3
4
3G/HD/SD SDI OUT
Open the front panel
and shut down the
USF-105S power
supply.
Slot 1 is the top slot in the left module block in the
rear panel. Remove the blank panel by detaching
the two screws on both ends. Keep the blank panel
and screws in a safe place after removal.
Insert the rear module into
the slot and fasten both
screws.
Loosen the two thumbscrews of the front
panel by turning them counterclockwise.
Pull out the front panel grasping the
thumbscrews. Cooling fans stop
while the front panel is open.
TEMP
FAN
DC 2
DC 1
ALARM
ON
POWER
USF-105S
UNIVERSAL
SYSTEM FRAME
LOCK
LOCK
Pull out the front panel.
(1)
(3)
(4)
(4)
(2)
Guide Rail
Guide Rail
Guide Rail
Guide Rail