![FOR-A USF-1040VEA Operation Manual Download Page 9](http://html.mh-extra.com/html/for-a/usf-1040vea/usf-1040vea_operation-manual_2316626009.webp)
9
4. Front Module DIP Switch Settings
The DIP switch settings listed in the table below are available on the front module.
Set the switches before installing the module into a frame.
Function
Switch
Switch Setting
Description
Coupling
(*1)
JP1
JP2
DC (Factory Setting)
DC coupling (1-2 Short)
AC
AC coupling (2-3 Short)
Clamp
SW 2
ON
Pedestal Clamp on
(*2)
OFF (Factory Setting)
Pedestal Clamp off
LOCAL/REMOTE
(*3)
SW 3
LOCAL
(Factory Setting)
COMPENSATION is set on the front panel
not via Web GUI.
REMOTE
COMPENSATION is set via Web GUI.
Front panel setting of COMPENSATION is
disabled.
SW 4
LOCAL
(Factory Setting)
GAIN is set on the front panel, not via Web
GUI.
REMOTE
GAIN is set via Web GUI. Front panel
setting of GAIN is disabled.
SD/HD
SW 5
SD (Factory Setting)
Used to input composite or SD analog
component signal.
HD
Used to input HD analog component or
tri-level sync signal.
(*1)
Set two switches to the same setting.
(*2)
When used as CLAMP ON, some signals are not applicable due to video format. Refer to
Sec. 9-1.
“Specifications” for details.
DC fluctuation of analog output can be suppressed using AC coupling/CLAMP ON for the
input signal with large DC-voltage fluctuation.
(*3)
Set the SW3 and SW4 to LOCAL when the USF-VEAIF option is not installed.
Installing a USF-VEAIF enables USF-1040VEA/1100VEA status displays. Set both SW3
and SW4 to REMOTE to set GAIN and COMPENSATION through Web GUI. Refer to Sec.
7.
“Web GUI” for details.
REMOTE/LOCAL Switching
SW 3, SW 4
Coupling Setting
JP1, JP2
CLAMP Setting
SW 2
HD/SD Setting
SW5