20
5. System Settings
5-1. Selecting Video Format
1) Press SYSTEM button. SYSTEM menu as below will be displayed on the output screen.
2) Move cursor to the menu item to make setting by using
←
→
↓
buttons.
Item
Description
Options
FMT Video
format 1080i 720p 525
625
RATE Sampling
frequency
59.94, 60, 50
59.94, 60
60
50
1080/59.94i
B.B., TRI
720/59.94p, 720/60p,
1080/60i, 1080/50i
TRI
REF IN
External reference
signal
525/60, 625/50
B.B.
3) Place cursor on the selected menu item, and press
↓
button.
4) Change the value by using
←
→
buttons. Press ENTER button to confirm the change.
5) After completing settings, use
↑
button to move into other menu. Press MENU CLEAR
button to exit menu and go back to video display.
5-2. System Initialization
Menu settings can be initialized.
1) Press SYSTEM button. SYSTEM menu will be displayed on the output screen.
2) Move the cursor to the menu INIT by using
→
button.
3) Move the cursor to OFF below the menu item EN by using
↓
button.
4) Change the value OFF to ON by using
←
→
buttons.
5) Press ENTER button. All the settings except video format are initialized.
6) After completing settings, use
↑
button to move into other menu. Press MENU CLEAR
button to exit menu and go back to video display.
IMPORTANT
The initialization process takes few seconds. The output display gets distortion during
the process.
FMT
VIDEO
RATE
REF IN
1080i
59.94
B.B.
[SYSTEM menu]
INIT ANCI GLINK
EN
EN
EN
OFF
OFF
ON
FMT
VIDEO
RATE
REF IN
1080i
59.94
B.B.
[SYSTEM menu]
INIT ANCI GLINK
EN
EN
ON
OFF
ON