6. LCD Indicators (HVS-AUX16C/16D)
LCD button displays are installed on HVS-AUX16C and HVS-AUX16D.
They can display assigned signal names, unit name, AUX ID, page no. and target switcher (See the
table below.)
See the Operation Manual of the destination unit for details on inputting display letters.
Display
How to display
AUX ID
HVS-AUX16C: Always displays
HVS-AUX16D: Displays for a second after operation or when the
rotary encoder is pressed and held.
Page
Destination
Displays while the rotary encoder is pressed and held.
6-1. Switching Pages
Turning the rotary encoder allows you to switch pages. PAGE1 displays buttons 1-16, PAGE 2
displays buttons 17-32, PAGE 3 displays buttons 33-48 and PAGE 4 displays buttons 49-64.
6-2. FMT Setting
LCD button displays on HVS-AUX16C/16D show up to 14 characters in two lines. When total
character number is 6 or less, the text is centered in a line regardless of the FMT setting.
Select a feed line setting from
FIX
or
AUTO
.
(1) Press SETUP. LCD button displays are switched to SETUP menu mode.
(2) Press AUX SET2.
(3) Press and hold --FMT--. The button starts to blink.
(4) Select
FIX
or
AUTO
by turning the rotary encoder.
FMT Setting
Description
FIX
(Default)
Breaks the line after 7 characters. 6 characters or less text is centered.
AUTO
Automatically breaks the line. When the line feed point is not judged, operates
as
FIX
.
See Appendix 1. “Auto Line Feed Line” for details.
(5)
Press and hold
SAVE. The screen returns to operation mode.