![FOR-A HVS-390HS Operation Manual Download Page 46](http://html1.mh-extra.com/html/for-a/hvs-390hs/hvs-390hs_operation-manual_2316756046.webp)
46
To Disable M/E Bank Operation
Users can inhibit M/E Bank operation by setting
M/E1
and/or
M/E2
to OFF under
M/E
CONTROL
on PAGE 2. All operations including bus signal selections and transitions cannot be
performed on the disabled M/E bank.
INPUT : M/E CONTROL : :INHIBIT: 2/6
OU ASSGN:ME1=
OFF
:ME2=
ON
: : =ENABL:
Note that KEY ON AIR and KEY AUTO buttons for KEY3 and KEY4, however, are still active on
the disabled M/E, if KEY3 and KEY4 are displayed on AUX outputs (AUX1-8).
5-3. How to Display Signal Names on the Bus Section
Information displayed above bus buttons on each M/E can be set on the menu.
(1) Open [SETUP - INPUT - ASSIGN] menu PAGE 3.
(2) Turn F1 to select a bus button.
(3) Turn F2 to select a display type. (See the table below.)
(4) Setting INV to ON changes tests or images to reverse video.
INPUT :BUTTON : TYPE : INV : : 3/6
BUS DISP: =01 : =SHORT: =OFF : :
Submenu Parameter
Setting range
Description
BUS DISP
BUTTON
1 to 28, sft1 to sft28 (*1) Selects a bus button.
TYPE
OFF Displays
nothing.
SHORT
Displays short signal names
(up to 4 characters).
LONG
Displays long signal names
(up to 8 characters).
BMP
Displays bitmap images.
INV
OFF
Displays text or images in normal video.
ON
Displays text or images in reverse video.
(*1) The number of buttons varies depending on the OU type.