10.-
SUBWOOFER PROTECT
: LED subwoofer protection signal indicator. It lights up when the line array
protection is activated. With the protection activated it cuts off the subwoofer audio output. In this case,
switch off the line array, correct the causes of the fault and let the device reset itself for a few minutes
before switching it back on again.
11.-
FULL RANGE GAIN
: full range output signal gain control.
12.-
FULL RANGE CLIP
: LED signal peak indicator of the full range signal. If it lights up slightly or
occasionally the full range gain must be reduced. If the LED indicator remains continuously lit, it is due
to the input signal having a very high level. In this case, reduce the input signal gain.
13.-
FULL RANGE PROTECT
: LED protection indicator of the full range output. It lights up when the line
array protection is activated. With the protection activated the full range audio output is cut off. In this
case, switch off the line array, correct the causes of the fault and let the device reset itself for a few
minutes before switching it back on.
14.- Power supply voltage selector 115/230 V AC.
15.- Power supply 115/230 V AC.
16.-
POWER
: loudspeaker on/off switch.
17.-
OUTPUT
: amplified and filtered signal output (contains mid and high frequencies) for the connection of
passive loudspeakers, loudspeaker connector.
FULL RANGE REAR PANEL
1.-
INPUT
: amplified and filtered signal input (contains mid and high frequencies).
2.-
OUTPUT
: amplified and filtered signal output (contains mid and high frequencies) for the connection of
another loudspeaker from the full range set.
- 5 -
EN