114
Smoke safety device interception
To restore functioning unscrew the lid of the thermostat and reset the button underneath (fig.
6). If the failure should occur again, call the Authorised Technical Service for assistance.
6 5
–
Default values
To take the setting to the default values, press the
and
keys at the
same time for at least 3 seconds. As confirmation a sign will appear on the display.
19
ATTENTION
The values of the following line numbers previously entered will be lost.
• Temperature and time programme
to
• Vacation period
1
10
18
–
Vacation function
To enter the number of days of absence.
In the display the vacation symbol will be shown (
), on the left the day of activa-
tion (1 = Monday/7 = Sunday) and on the right the number of vacation days.
18
During the vacation the regulator will be on the availability mode.
When the set days have elapsed, the regulator will go on to the automatic function.
NOTE:
The vacation period may be cancelled by pressing a key of the operating mode.
–
Current values
Display and setting of the gradient of the heating characteristics curve.
When the room temperature set is not reached choose the gradient
indicated in point 2.7.3
Display of the current boiler temperature.
Display of the current power of the burner and of the current operating mode
(
= = heating/
= hot-water service)
15
16
1 7
–
Setting the time
To set the current day of the week
(1 = Monday/7 = Sunday)
To set the current hour
To set the current minute
Once the hour is completed, the setting of the hour changes.
12
13
14
With
and
keys the current hour is regulated. Pressing these keys together, the
regulation is speeded up in an increasing sense.
1
0
–
Display of the functioning faults on the display
Starting failure
Turn the selector CR/OFF/SUM/WIN/UNBLOCK from the
“LOGO”
control panel to the
unblock position (
) to restore functioning (fig. 3). If the failure should occur again, call the
Authorised Technical Service for assistance.
Thermostat safety interception
Turn the selector CR/OFF/SUM/WIN/UNBLOCK of the
“LOGO”
control panel to the unblock
position (
) to restore functioning (fig. 5). If the failure should occur again, call the Authori-
sed Technical Service for assistance.