109
–
Safety stat interception
(fig. 5)
If the safety thermostat intercedes the
red led “35 °C” intermittently lights up. To
start the boiler again, turn the selector
knob in the position (
)and then release
immediately, returning it to the winter
(
) or summer (
) function.
If the failure should occur again, call
the Authorised Technical Service for
assistance.
–
Smoke safety device
interception
(fig. 6)
I n c a s e o f p e r t u r b a t i o n d u r i n g t h e
discharge of the fumes the safety switch
int er cedes and t he f lashing r ed led
“40°C” lights up.To attempt to start the
boiler again, unscrew the cover of the
thermostat and reset the button under-
neath.
After 10 minutes from the resetting, the
boiler will automatically restart. For an
immediate restarting, after having reset
the thermostat, turn the boiler off and
wait a few seconds before restarting it.
WARNING:
The safety switch must never be put
out of use.
Tampering with the device could cause
serious faults.
In case of replacement or repair only
original parts must be used.
Repeated interceptions by the device
require the assistance of the Technical
Service Centre.
R E M O T E
SPIA ROSSA INTERMITTENTE
Fig. 5
R E M O T E
SPIA ROSSA INTERMITTENTE
Fig. 6
FLASHING RED LED
FLASHING RED LED