101

3.1

ELECTRONIC BOARD

Made  in  accordance  with  the  Low  Voltage

EEC  directive  73/23,  supplied  with  230  V;

via  a  transformer  it  sends  24  V  to  the  fol-

lowing  components:  gas  valve,  safety  stat,

C.H. and D.H.W. sensors, external tempera-

ture  sensor  (optional),  modulator,  micro

diver tor  valve,  flow  switch  safety  valve,

water pressure transducer, smoke pressu-

re switch, smoke stat, room stat or “Logica

Remote Control”. 

An  automatic  and  continuous  modulating

system  allows  the  boiler  to  adjust  the

p o w e r   t o   t h e   v a r i o u s   p l a n t   o r   u s e r

demands.  The  electronic  components  are

guarant eed  t o  work  in  a  t emperatur e

range between 0 and +60 °C.

3.1.1

Faults findings

The  leds  that  show  an  irregular  and/or

incorrect  functioning  of  the  boiler  are

shown in fig. 9.

3.1.2

Devices 

The  electronic  board  has  the  following

devices:

Trimmer “POT. RISC.” 

(10 fig. 10)

It  regulates  the  maximum  value  of  hea-

ting  power.  To  increase  the  value  turn

the trimmer in a clockwise direction and

to  decrease  it  turn  the  trimmer  in  an

anti-clockwise direction.

Trimmer “POT. ACC.” 

(6 fig. 10)

Trimmer  for  the  changing  of  the  ignition

pressure  level  (STEP)  of  the  gas  valve.

According to the type of gas for which the

boiler  is  predisposed,  the  trimmer  must

be regulated so as to provide the burner

with  a  pressure  of  around  8  mbar  for

methane  gas  or  18  mbar  for  propane

gas (G31). To increase the pressure turn

the  trimmer  in  a  clockwise  direction,  to

decrease  it  turn  the  trimmer  in  an  anti-

clockwise direction. The level of pressure

of  slow  starting  is  able  to  be  set  during

the  first  5  seconds  from  the  starting  of

the burner. 

After having established the

level  of  pressure  at  starting  (STEP)

according to the type of gas, check that

the heating gas pressure is still on the

value set beforehand.

Connector “MET-GPL” 

(7 fig. 10)

With  the  connector  disconnected,  the

boiler is ready to function with MET; with

the connector connected with GPL.

Connector “ANN. RIT.” 

(5 fig. 10)

The  electronic  board  is  programmed,  in

heating phase, with a technical pause by

the  burner  of  around  90  seconds,  both

at  the  beginning  when  the  plant  is  cold

and in the subsequent startings. 

This is so to avoid ignitions and switching

off  with  very  short  intervals,  that  may  in

particular  be  found  in  plants  with  high

losses.  At  every  restarting,  following  the

period of slow starting, the boiler will posi-

tion itself for around 1 minute to the mini-

mum modulating pressure to then return

to the set value of heating pressure.

With  the  insertion  of  the  bridge  both

the  technical  pause  programmed  and

the  period  of  functioning  at  minimum

pressure  in  the  starting  phase  will  be

eliminated.  In  such  a  case,  the  time

that  runs  between  the  switching  of f

and the next starting will be in function

of  a  variance  of  5  °C,  as  shown  by  the

heating feeler (SM).

DIP SWITCH 

(13 fig. 10)

In the 

“32/80 OF”

version and in the 

“22

OF  -32  OF”

versions  connected  to  the

“BT130- BT150”

D.H.W. tanks, the riders

must have the configuration shown in the

figure in order for the boiler to work:

In  the  version 

“32/50  OF”

,  instead,  the

riders must have the configuration shown

in the figure for the boiler to function:

Connector “Modureg Sel.”  

(14 fig. 10)

With  the  bridge  disconnected  the  boiler

is  predisposed  to  function  with  the  SIT

gas valve, and with the bridge connected

it  is  predisposed  to  function  with  the

HONEYWELL gas valve.

3

CHARACTERISTICS

Green led off 

in case of no electricity

Red led flashing in case of 

insufficient water pressure

Red led flashing - problem with D.H.W. sensor (SB).

The function is active in the versions 

“22 OF - 32 OF”

only when the boiler is connected to a tank unit 

“BT130-BT150”

Red led flashing - problem with C.H. sensor (SM)

Red led flashing - coil of the modulator stopped

Red led flashing - problem in flame detector circuit

Red led flashing 

in case of plant safety 

valve interception

Red led flashing - lack of 

communication with the

“Logic Remote Control”

Red led on - starting failure 

turn the selector

CR/OFF/SUM/WIN/UNBLOCK 

in the position unblock  ( ) 

to restore functioning

Red led flashing - safety stat 

interception. To restore functioning 

turn the selector

CR/OFF/EST/INVE/UNBLOCK 

in the position unblock ( ) 

Red led flashing - smoke safety device

interception. To restore functioning 

reset the thermostat button. 

After 10 minutes the panel 

will reactivate the boiler.

Fig. 9

Summary of Contents for LOGO 22 OF

Page 1: ...e boiler is set for operation for the type of gas supplied Check that the flue pipe for the outlet of the products of the combustion is unobstructed Make sure that any shutoff valves are open Make sur...

Page 2: ...50 D H W tanks LOGO 32 50 OF 32 80 OF central heating and D H W production electronic ignition and modulation natu ral draught Follow the instructions given in this manual for the correct installation...

Page 3: ...tank unit BT150 version CONNECTIONS M C H flow 3 4 M R C H return 3 4 M E D H W inlet 1 2 M G Gas connection 3 4 M U D H W outlet 1 2 M C Re circulation 1 2 F S1 Safety valve drain 1 2 F S2 D H W tank...

Page 4: ...D H W circulating pump 10 C H circulating pump 11 Gas valve 12 Burners 13 Non return valve 14 Burners manifold 15 Water pressure transducer 16 Boiler drain cock 17 D H W expansion vessel 18 D H W safe...

Page 5: ...40 80 40 80 40 80 40 80 D H W setting range C 10 60 10 60 10 60 10 60 Category II2H3P II2H3P II2H3P II2H3P Type B11BS B11BS B11BS B11BS Smokes temperature C 108 110 116 119 Smokes flow gr s 18 5 23 2...

Page 6: ...W expansion vessel 5 Manual filling group 6 D H W tank 7 D H W tank drain cock 8 Boiler drain cock 9 Burners manifold 10 Pilot burner 11 C H circulating pump 12 Gas valve 13 Gas pressure switch 14 Saf...

Page 7: ...connect up the boiler you are recommended to make the air cir culating in the piping in order to eliminate any foreign bodies that might be detrimen tal to the operating efficiency of the applian ce...

Page 8: ...t this operation check that the filling tap is closed 2 5 FLUE The flue for the atmospherical expulsion of the combustion products from natural draught appliances must meet the following requirements...

Page 9: ...nector ends 3 dama ges irreparably the control panel Before the connection make sure that there is no voltage 2 6 2 Logica Remote Control connection fig 6 pos B The electrical systems must be in com p...

Page 10: ...on the inspection control and cleaning flange of the tank 2 6 5 Wiring diagram J7 J5 J4 J3 J2 KEY TR Transformer 230 24V TRA Ignition transformer P C H circulating pump PB D H W circulating pump EA I...

Page 11: ...through a window contact Anti bacterial 2 7 1 Installation The unit must be installed in the main living room For installation follow the assembly instructions inserted in the package At this point w...

Page 12: ...until it finds the optimum switch off time 59 60 SETTING THE HOT WATER SERVICE PARAMETERS Reduced hot water temperature value Hot water service filling The hot water may be set to a reduced temperatu...

Page 13: ...witch over to reduced pre set value of the ambient temperature 3 With an external contact it is possible to switch over to reduced pre set value of the antifreeze ambient temperature short circuit 0 0...

Page 14: ...eginning when the plant is cold and in the subsequent startings This is so to avoid ignitions and switching off with very short intervals that may in particular be found in plants with high losses At...

Page 15: ...ntinuous jump spark from the electrode is noted despite the pilot burner being lit After 20 seconds the sparking stops the burner goes off and the block signal lights up The cable of the detector elec...

Page 16: ...PERTURA TA 6 SB 11 SB 12 CIRCUITO CON VALVOLE DI ZONA NOTA I rel vengono impiegati solo nel caso le valvole di zona siano prive di micro L N TA TA1 VZ R VZ1 R1 NOTA PER VERSIONI SOLO RISCALDAMENTO Sos...

Page 17: ...g potentiometer knob on the maximum value Using a 10 wrench turn the nut 3 to find the maximum pressure as shown in Table 2 to reduce the pressure turn the nut anti clockwise to increase the pres sure...

Page 18: ...ENANCE Carry out the cleaning of the generator in the following way fig 18 Remove the electricity supply to the boi ler and close the gas supply tap Dismantle the gas group completely Dismantle the li...

Page 19: ...erature always with the primary circuit controlled between 80 C and 70 C During the entire duration of the testing the hot water taps must remain open After verifying the combustion the boiler should...

Page 20: ...C and the yellow led of the hot water will light up at the same time In the versions with storage capacity when there is no request for hot water service and heating the leds and are off the operatin...

Page 21: ...ed Technical Service between April and September The boiler comes with an electricity supply cable which in case of replacement must be requested only from SIME FAULT FINDING Starting failure fig 3 If...

Page 22: ...hts up To attempt to start the boiler again unscrew the cover of the thermostat and reset the button under neath After 10 minutes from the resetting the boiler will automatically restart For an immedi...

Page 23: ...he boiler will function by placing the selector on the o position obviously without consequent control of the room temperature The functioning instructions are inside the lid fig 9 Every setting or mo...

Page 24: ...l lowing list of items one after the other are displayed The thermo feeler continues to function independently of the display Day hour room temperature External temperature Hot water service temperatu...

Page 25: ...ity boiler unit temperature desired for hot water service at reduced level To have access to the reduced hot water service temperature parameter press the and keys at the same time for at least 5 seco...

Page 26: ...rature set in parameter 3 1 standard Hot water according to the daily heating programme In the comfort periods of the heating the temperature of the boiler unit is regulated at the value set via para...

Page 27: ...ode Current values Display and setting of the gradient of the heating characteristics curve When the room temperature set is not reached choose the gradient indicated in point 2 7 3 Display of the cur...

Page 28: ...oning by acting on the filling tap of the boiler fig 4 Plant overpressure Call the Authorised Technical Service for assistance Thermostat safety interception Call the Authorised Technical Service for...

Reviews: