Plumbing
Dispenser
3/4" PVC slip joint for hopper drain
3/4" PVC pipe nipple for beverage drain pan
3/8" ID red line tubing for water in
Note
: Drains should be hard piped and insulated. Maintain at least 1/4" per foot (6mm per
304mm run) slope on drain line run.
Icemaker
R
efer to Icemaker Installation Manual packed with icemaker
1/4"
FPT
water
in
1/2"
MPT
drain
3/8" FPT condenser inlet (water-cooled condenser only)
1/2" FPT condenser drain (water-cooled condenser only)
Water disconnect within 10 feet (3m) of dispenser is suggested for automatic load units.
Clearance and access information
• 51" (1296mm) above counter
• 12" (305mm) on side opposite tower, below counter
• Counter front or rear panel must be removable for service access to both sides of dispenser and
icemaker(s), if any
• Below counter access to drain clean-out required on utility side of dispenser
4
31.25
12"
(305mm)
(794mm)
"
electric
conn.
18.875"
(480mm)
17"
(432mm)
6" min
(153mm)
one remote icemaker
models U155NR400A/W
two remote icemakers
models U155NR800A/W
21.75"
(553mm)
28"
(712mm)
49.75"
(1264mm)
and drain
clean-out
12" min
(305mm)
plain
water
Manual load units
Automatic load units with 1 icemaker
Automatic load units with 2 icemakers
Front view
Side view - right hand dispenser
(side opposite dispense tower)
26"
(661mm)
5.25"
12"
27.375"
(305mm)
(696mm)
(134mm)
26"
(661mm)
3.5"
(89mm)
3/4" PVC
slip joint
drain
air break:
do not
connect
to drain
system
ice
transport
tube
entrance
plain water