Condenser
u
nit
Maximum line
hei
g
ht
Condenser
u
nit
S - trap install
re
qu
ired
Condenser
u
nit
Maximum line
drop
35 ft
(10.7m)
20 ft+
(6.1m)
-15 ft
(-4.6m)
3 ft+
(.9m)
Refrigeration line
elevation specifications
System layout
Clearances
Installation
Specifications
Outdoor ambient temperature range: – 20°F – 130°F
(– 29°C – 54.4°C).
Indoor ambient temperature range: 50°F – 90°F
(10°C – 32°C).
Installations with condenser unit above indoor unit
require a suction line S-trap at the bottom of the rise.
Installation with condenser unit elevations above 20 ft (6.1m)
require an additional S-trap at the midpoint of the rise.
Maximum line rise must not exceed 35 ft (10.7m).
Maximum line set length must not exceed 100 feet (30.5m).
Max line drop must not exceed 15 ft (4.6m).
Note:
The service loop is not included when calculating the
length, rise or drop of the tubing run.
Water pressure 10 psi – 70 psi.
Water temperature 50°F – 90°F (10°C – 32°C).
Install condenser unit
Mount condenser unit
1.
Level
unit.
2. Securely attach base of unit using holes found in
base
plate.
Electrical connection
Refer to wiring schematic located in condenser unit
electrical
box.
Note:
Electric disconnects required within 10 ft (3m)
for
all
hard-wired
connections.
Note:
Install in accordance with NEC and local
electrical
codes.
Air flow
Discharge air
60"
(1524mm)
24"
(610mm)
6"
(153mm)
6"
(153mm)
8" (204mm)
12" (305mm)
8" (204mm)
Condenser unit
Evaporator
5
Installation
Icemaker performance is very sensitive to the quality of installation. To ensure proper performance, ease of
service and warranty coverage, it is critical that you follow the requirements detailed in this manual. If you cannot
meet these requirements or have questions, call our technical service group immediately at (800) 523-9361 or
(610) 252-7301.