Follett C125A Installation, Operation And Service Manual Download Page 1

12 Series

Ice and Water Dispensers 

Installation, Operation and Service Manual 

207805R02

801 Church Lane • PO Box D • Easton, PA 18044
Toll free (800) 523-9361 • (888) 2-FOLLETT
(610) 252-7301 • Fax (610) 250-0696 • www.follettice.com

®

UL

®

C125A 

countertop dispenser

C125A 

countertop dispenser with

SensorSAFE

actuation (shown

with legs accessory)

H125A 

wall mount dispenser (available

with or without drain pan)

Following installation, please forward this manual 

to the appropriate operations person.

Order parts online
www.follettice.com

Summary of Contents for C125A

Page 1: ...2 FOLLETT 610 252 7301 Fax 610 250 0696 www follettice com UL C125A countertop dispenser C125A countertop dispenser with SensorSAFE actuation shown with legs accessory H125A wall mount dispenser avail...

Page 2: ......

Page 3: ...l and diagnostic sequences 16 Refrigeration cycle diagram 21 Icemaker capacity chart 22 Icemaker data 22 Refrigeration system data and requirements 23 Dispenser troubleshooting lever SensorSafe models...

Page 4: ...er you have Follett model numbers are designed to provide information about the type and capacity of Follett ice dispensing equipment Following is an explanation of model numbers 4 C125A Condenser typ...

Page 5: ...ressure 70 P S I Max 10 P S I Min Plumbing specifications C125A H125A Dispenser drain 3 4 FPT 3 4 FPT Water inlet 3 8 FPT 3 8 FPT Note Water shut off recommended within 10 feet 3m of dispenser Drain t...

Page 6: ...around outside of dispenser 7 Make final connections cutout for connections through bottom 404mm 458mm 102mm 38mm 1 26mm 305mm 305mm 266mm 407mm 2mm 51mm 16 14 4 12 0 8 1 5 2 12 15 9 18 4 Fig 1 437 di...

Page 7: ...crews Fig 4 5 Make final connections 7 407mm 39mm 9 23mm 298mm 206mm 16 11 7 8 1 1 5 Rear exiting utilities countertop units 3 8 FPT water inlet 3 4 FPT drain power cord Fig 3 Bottom exiting utilities...

Page 8: ...ispenser weight on bottom of support bracket wall mounting bracket screw support bracket Fig 5 Fig 6 458mm 572mm 826mm 22 5 32 5 18 bottom of dispenser WALL PREPARATION Wall and fasteners must be of s...

Page 9: ...wn water and drain tubing 407mm 77mm 3 254mm 3 5 3 77mm 1 25 32mm MAX 77mm 89mm 77mm MIN 0 88 23mm MIN 16 10 3 3 nut support bracket screw bottom panel 3 4 FPT drain 3 8 FPT water inlet Wall mount uni...

Page 10: ...t turned back on after cleaning the dispenser automatically resets after two minutes for normal operation SensorSAFE also includes a time limit safety feature which automatically stops ice dispensing...

Page 11: ...ter conditions dictate Failure to clean icemaker will result in decreased performance and potential damage to icemaker 1 Disconnect power to unit 2 Remove front panel as shown on page 30 to gain acces...

Page 12: ...ate ice transport tube to evaporator and divert ice into separate container 16 Fill reservoir almost to overflowing with sanitizing solution 17 Restore power to icemaker and turn compressor switch to...

Page 13: ...Water is supplied to the evaporator from the water reservoir where the water level is controlled by a float valve This valve also shuts off the water supply when the icemaker is not running When the...

Page 14: ...ACK 10 GREEN 12 TERMINAL BLOCK POWER SWITCH GREEN 27 x DRIVE FAN COMP L2 L2 I D SOFTWARE L2 L2 L2 EARTH L1 L1 I D LABEL A SENSOR W TER B E WTR B T 2ND 60M 20M C DR RESET ELEC BOX POWER x GRN IN WATER...

Page 15: ...provide touchless ice and water dispensing When a container is placed within the actuation zone below the ice or water chute an invisible randomly generated infra red signal is emitted reflected off t...

Page 16: ...he reservoir The Bin Empty LED B E will be on M GRD L1 L1 L2 L2 L2 L2 L2 COMPRESSOR FAN DRIVE DR C 20M 60M 2ND WTR B T B E RESET X GRD G B W FAN BLACK WHITE BLACK BLACK R ORANGE S S L COMPRESSOR C RED...

Page 17: ...emaker is now in a normal icemaking mode The icemaker will begin to produce ice and continue to produce ice until the bin level control in the ice dispenser is satisfied The B E DR C and WTR LEDs are...

Page 18: ...aker for troubleshooting purposes press the reset button to clear the control board M GRD L1 L1 L2 L2 L2 L2 L2 COMPRESSOR FAN DRIVE DR C 20M 60M 2ND WTR B T B E RESET X GRD G B W FAN BLACK WHITE BLACK...

Page 19: ...the control board will try to go through a normal start up sequence The WTR LED remains on as long as the water sensor in the float reservoir senses water M GRD L1 L1 L2 L2 L2 L2 L2 COMPRESSOR FAN DRI...

Page 20: ...rred The icemaker will be shut down at this time and will not restart unless the manual reset button is pressed M GRD L1 L1 L2 L2 L2 L2 L2 COMPRESSOR FAN DRIVE DR C 20M 60M 2ND WTR B T B E RESET X GRD...

Page 21: ...D BLACK GEARMOTOR 24V COMMON LINE VAC RED RED WHITE BLACK BIN T STAT BIN SIGNAL FROM DISPENSER JUNCTION BOX WHITE RED WHITE M 1 4 3 L1 L2 HI TEMP SAFETY T STAT W C ONLY COMPRESSOR SWITCH WATER SENSOR...

Page 22: ...mp 60 F 15 6 C 70 F 21 1 C 80 F 26 7 C 90 F 32 2 C 100 F 37 8 C 6 3A 6 5A 6 7A 6 9A 7 1A Locked rotor amps 48 0 Table 3 Gearmotor data Gearmotor current 2 25A nominal Locked rotor amps 14 amps 22 50 4...

Page 23: ...n the 50 micron level is reached shut the vacuum pump down Allow the system to sit for approximately 30 seconds During this period the system should not rise above 1000 microns If the system rises abo...

Page 24: ...e dispense switch a Check for proper positioning If stat does not open when ice is placed on capillary tube replace stat a Replace water solenoid valve b Replace dispense switch c Check switch turn on...

Page 25: ...t lens and sensor assembly for foreign material and remove using non abrasive cleaner Turn dispenser power on and test sensor by moving hands through activation area no closer than 3 16 1 9mm in front...

Page 26: ...low to condenser coil 3 Mineral coated evaporator 4 High ambient water supply and or air temperature 5 Improper exhaust air provisions 6 Faulty expansion valve 7 Low refrigerant charge 8 Superheat inc...

Page 27: ...ntilation 5 Defective compressor 1 Clogged or dirty condenser coil 2 Compressor not pumping 3 Low refrigerant charge 1 Compressor switch in off position 2 No output on compressor and fan motor termina...

Page 28: ...rive bar in this sequence Wheelmotor removal 1 Remove dispense wheel and drive bar see above 2 Remove four 4 hopper support plate mounting screws and washers see drawing below 3 Move hopper assembly 1...

Page 29: ...ll evaporator mounting base 4 Fill gearmotor shaft well with food grade grease 5 Install condensate shield and seat against gearmotor boss 6 Install bearing O ring in groove in evaporator mounting bas...

Page 30: ...toward back of unit and pull fan assembly toward front of unit c As fan assembly is being pulled toward front rotate assembly clockwise as shown above Fan removal Side panels Remove screw located on...

Page 31: ...ube may extend a maximum of 1 4 into ice bin 31 Top view 25 ice tube gasket ice tube retainer 50 TYP 3 2 capillary tube bracket Ice transport tube replacement 1 Soak end of transport tube in hot water...

Page 32: ...assembly includes base pan and grille 6 502394 Panel rear 7 502399 Leg kit 4 101mm adjustable set of 4 8 502415 Fitting water inlet 9 502397 Lid top panel plastic 10 502396 Panel right side 11 502395...

Page 33: ...otating 9 502406 Bracket capillary tube See page 28 502404 Retainer ice tube See page 28 502405 Gasket ice tube See page 28 502413 Assembly hopper includes drain fitting 10 500504 Float valve and rese...

Page 34: ...418 Boot dispense switch button mounts over the dispense button 7 502057 Fastener dispense chute assembly 4 required 8 501250 Screws dispense lever 9 502427 O ring 10 502561 Fitting 1 4 tube 11 502562...

Page 35: ...1 Assembly sensor and mounting block includes 502239 and 502240 6 502239 Block sensor mounting 7 502240 Sensor 8 501100 Thumbscrew 9 502401 Cover dispense chute water 10 502400 Cover dispense chute ic...

Page 36: ...r 115V 60Hz 15 501583 Compressor 115V 60Hz 16 501191 Tubing plastic food grade 1 2 ID sold by the foot 17 500623 Tubing plastic 5 8 ID x 13 16 OD sold by the foot 18 502079 Tubing polypropylene reserv...

Page 37: ...LE LC125A 207959 CHARGE 24 OZS REFRIGERANT R 22 PANELS REMOVED CAUTION HAZARDOUS MOVING OPERATE UNIT WITH PARTS DO NOT 1 10 5 6 8 7 18 16 15 11 12 14 13 2 17 3 4 9 19 20 21 24 Rear view Right side vie...

Page 38: ...Board control circuit 115V 60Hz 3 502116 Water sensor 4 502392 Switch on off compressor 5 502209 Switch rocker power 6 502209 Switch rocker bin signal 7 502409 Switch cleaning SensorSAFE models 8 502...

Page 39: ...evap includes 501063 12 502227 Bolt mounting base Not shown 501992 Gearbox motor assembly 13 501993 Gearbox motor assbly 230V 13 501190 Mounting base gearbox Not shown 502220 Compression nozzle w dou...

Page 40: ...nion assembly 18 500798 Shaft 2 gear 19 500878 4 Gear 5 pinion assembly 20 501989 Gearcase 21 501994 Vent plug 23 501991 Bearing ball sealed 24 501144 Bearing rotor top Not shown 501171 Switch centrif...

Reviews: