![Foerster TAK5-CH1-25 Instruction Manual Download Page 62](http://html1.mh-extra.com/html/foerster/tak5-ch1-25/tak5-ch1-25_instruction-manual_2314657062.webp)
62
Setup
4.8.1
Feed control
4.8.1.1 Internal stations controlled by the automatic feeder
The Compact is designed for connection of max. two feeding
stations. The two internal controls required for that are part of the
standard equipment of the automatic feeder.
With the Vario both internal controls are also available and
useable. In addion, further stations can be controlled as so-
called IFS-stations (see
Select the internal control to be allocated.
Allocation
In
allocation
select the feeding station which is to be allocated
to the internal control.
Options
In
options
select whether a gradient or servo control is con-
nected.
Teat slider
If the station is equipped with a teat slider, select
teat slider
closed
resp.
open
.
Closed
means that the teat slider remains
closed until an entitled animal enters the feeding station. If the
animal has no feed entitlement anymore, the teat slider will close
again.
Open
means that the teat slider remains open until a non-
entitled animal enters the feeding station. After an entitled animal
has entered the station and consumed its feed, the teat slider will
close and open again when an entitled animal enters the station
resp. opening time has lapsed.
F-stations
internal (device)
IFS-F single
IFS-F quadruple
<internal 1>
allocation: [station 1]
options: none
teat slider: no
Summary of Contents for TAK5-CH1-25
Page 38: ...38 Operation ...
Page 54: ...54 Start up ...
Page 70: ...70 Setup ...
Page 84: ...84 Device data ...
Page 90: ...90 Calibration ...
Page 150: ...150 Cleaning ...
Page 170: ...170 Animal control ...
Page 192: ...192 Failures and warnings ...
Page 196: ...196 Care and maintenance plan Routine tasks ...
Page 215: ......
Page 218: ...218 Annex 16 3 5 Template for individual feeding plan ...
Page 219: ...Annex 219 16 4 Basic principle of interval feeding ...
Page 222: ...222 Annex ...