![Foerster TAK5-CH1-25 Instruction Manual Download Page 49](http://html1.mh-extra.com/html/foerster/tak5-ch1-25/tak5-ch1-25_instruction-manual_2314657049.webp)
Start-up
49
Recommendations for temperature settings
The automatic feeder and the heat exchanger are designed in
such a way that also milk powders with higher fat melting point
can be used without any problems. Make sure that the feed tem-
perature in the mixer jar is between 42 ºC and 43 ºC.
If you solely use whole milk or cold-soluble milk powders, a lower
temperature of the feed in the mixer jar may be sufficient (e. g.
38 ºC).
Set temperature Min. temperature
Default value:
41 ºC
38 ºC
Allowed range:
10 ºC to 44 ºC
0 ºC to set tempera-
ture minus 0.5 ºC
Note:
The values entered for the target and the minimum
temperature are converted to the target and the minimum
temperature of the boiler water. If the temperature of the
boiler water falls below the minimum temperature, feed
preparation will be broken off until the minimum tempera-
ture is achieved again.
Note:
If you want to deactivate the minimum temperature
parameter, in min. temp. enter
0 ºC
.
Warning
: Too low feed temperatures may cause digestive
troubles. Too high feed temperatures may lead to inflam-
mations of the mucosa in the abomasum.
Summary of Contents for TAK5-CH1-25
Page 38: ...38 Operation ...
Page 54: ...54 Start up ...
Page 70: ...70 Setup ...
Page 84: ...84 Device data ...
Page 90: ...90 Calibration ...
Page 150: ...150 Cleaning ...
Page 170: ...170 Animal control ...
Page 192: ...192 Failures and warnings ...
Page 196: ...196 Care and maintenance plan Routine tasks ...
Page 215: ......
Page 218: ...218 Annex 16 3 5 Template for individual feeding plan ...
Page 219: ...Annex 219 16 4 Basic principle of interval feeding ...
Page 222: ...222 Annex ...