Care and maintenance plan / Routine tasks
195
13.2 Shutdown of the automatic feeder and the peripheral devices
ok?
Empty and clean the milk powder hopper
.
Close the cable inlets of the antennas by means of blind plugs
.
Moisture may penetrate into the control unit if the inlets are not closed.
Carry out
circuit cleaning
.
Drain the water from the boiler
.
Remove the water hose located between the water solenoid valve and the boiler and open the
bleeder screw located at the boiler casing so that the water can drain off. When the boiler is com-
pletely empty, remount the water hose and tighten the bleeder screw.
Drain the water from the solenoid valves and the volume regulator
.
(In case of frost risk!)
Empty and clean the concentrate feeder
. Remove the CAN-Bus-cable and the antenna
cable.
Demount the weighing platform and clean it
. Remove the connecting cable of the scales
control.
Pull the mains plug
.
Store the devices in a frost-free location, if possible.
Summary of Contents for TAK5-CH1-25
Page 38: ...38 Operation ...
Page 54: ...54 Start up ...
Page 70: ...70 Setup ...
Page 84: ...84 Device data ...
Page 90: ...90 Calibration ...
Page 150: ...150 Cleaning ...
Page 170: ...170 Animal control ...
Page 192: ...192 Failures and warnings ...
Page 196: ...196 Care and maintenance plan Routine tasks ...
Page 215: ......
Page 218: ...218 Annex 16 3 5 Template for individual feeding plan ...
Page 219: ...Annex 219 16 4 Basic principle of interval feeding ...
Page 222: ...222 Annex ...