178
Failures and warnings
12.1.9
Boiler temperature sensor
If the temperature sensor in the boiler is defective, the failure
message on the right is displayed.
•
If in
boiler
or/and
mixer
0.0 °C is displayed, it can be as-
sumed that the data line is interrupted. If 99.9 °C is displayed,
it can be assumed that a short circuit occured.
Exclusively for service personnel:
> Remove the plug from the motherboard and measure the re-
sistance of the sensor.
> If the measured value deviates from the value contained in
the table, the sensor must be replaced (see wiring diagram of
the machine).
12.1.10 Milk/circulation valve
If the failure
milk/circ. valve
is displayed, it can be assumed that
the milk valve or the circulation valve is untight.
1. Carry out a function and visual check of both valves.
2. In
milk pump start?
press
. If, after the pump has start-
ed, some liquid flows out of the milk/water outlet, one of the
two valves is untight.
3. Let service personnel check and replace the valves, if neces-
sary.
4. Once the failure has been removed, in
delete failure?
press
.
5. Secure the metal covering and close the lat-
eral door.
6. Only then, plug in the mains plug or turn the
main switch to position ON.
failure
boiler sensor
boiler sensor
boiler: xx.x
o
C
mixer: xx.x
o
C
failure
milk/circ. valve
milk/circ. valve
milk pump: start?
milk: start?
cleaning: start?
Summary of Contents for TAK5-CH1-25
Page 38: ...38 Operation ...
Page 54: ...54 Start up ...
Page 70: ...70 Setup ...
Page 84: ...84 Device data ...
Page 90: ...90 Calibration ...
Page 150: ...150 Cleaning ...
Page 170: ...170 Animal control ...
Page 192: ...192 Failures and warnings ...
Page 196: ...196 Care and maintenance plan Routine tasks ...
Page 215: ......
Page 218: ...218 Annex 16 3 5 Template for individual feeding plan ...
Page 219: ...Annex 219 16 4 Basic principle of interval feeding ...
Page 222: ...222 Annex ...