174
Failures and warnings
12.1.5
Water shortage
If the
bar resp. the
supply electrode is not grounded in the
mixer jar during water dispense and the
water meter does not
transmit any pulses, the device will start a water check. If water
check fails, feed preparation and animal identification will be
switched off.
> Press
in
water bo. start?
.
> Press
in
water HE start?
.
> Check whether the water jet touches the
bar electrode re-
sp. the
supply electrode.
> Check the water supply to the automatic feeder.
> Press
in
delete failure?
.
>
Exclusively for electricity specialists
: Check the sensitivity
of the electrode:
The
sensitivity
of the electrode is:
•
too high
, if the electrode signals
covered
though it is actually
free.
•
too low
, if the electrode signals
water shortage
though it is
covered.
Note
:
Check whether the stop valves and the drain-
ing valve are tight. If some liquid in the mixer is drained
via one of these valves, the bar electrode may not be
grounded anymore.
failure
water shortage
water shortage
water bo.: start?
water HE: start?
bar el.: start?
supply el.: free
Summary of Contents for TAK5-CH1-25
Page 38: ...38 Operation ...
Page 54: ...54 Start up ...
Page 70: ...70 Setup ...
Page 84: ...84 Device data ...
Page 90: ...90 Calibration ...
Page 150: ...150 Cleaning ...
Page 170: ...170 Animal control ...
Page 192: ...192 Failures and warnings ...
Page 196: ...196 Care and maintenance plan Routine tasks ...
Page 215: ......
Page 218: ...218 Annex 16 3 5 Template for individual feeding plan ...
Page 219: ...Annex 219 16 4 Basic principle of interval feeding ...
Page 222: ...222 Annex ...