Cleaning
145
11.When circuit cleaning has been completed, the message on
the right will be displayed. Remove the suction hoses from the
cleaning adaptor. Reconnect the milk hose to the automatic
feeder and the milk tank and slip the suction hoses on the
hose nozzles of the teat. Confirm the message with
.
12.Now you can reactivate the automatic mode of the automatic
feeder.
9.5
Air (pulsating compressed air cleaning)
Compressed air cleaning allows you to clean the suction hoses
up to the top of the teat without need of using detergent. To
achieve efficient cleaning, the air pressure must be between 2
and 2.5 bar. The compressed air should be supplied by an oil-
free compressor with a capacity of 100 liters per minute and
which is equipped with a pressure reducer.
Compressed-air cleaning (hereinafter called air cleaning) can be
started automatically or manually.
1.
>
cleaning
>
air
2. In
start after
enter the time that should elapse after the last
portion has been dispensed before
air cleaning
starts run-
ning
automatically
.
3. If you want to
manually start
air cleaning, in
F-station
press
. Select the
feeding station
.
4. In
mode
select the intensity of air cleaning.
5. In
start
press
.
hoses
connected?
Caution
: If the air pressure is more than 2.5 bar, the dia-
phragm of the milk solenoid valves may be damaged.
air cleaning
start after: [ 30]min
F-station
<station 1>
start?
mode: [ medium ]
air cleaning
start after: [ 30]min
F-station
Summary of Contents for TAK5-CH1-25
Page 38: ...38 Operation ...
Page 54: ...54 Start up ...
Page 70: ...70 Setup ...
Page 84: ...84 Device data ...
Page 90: ...90 Calibration ...
Page 150: ...150 Cleaning ...
Page 170: ...170 Animal control ...
Page 192: ...192 Failures and warnings ...
Page 196: ...196 Care and maintenance plan Routine tasks ...
Page 215: ......
Page 218: ...218 Annex 16 3 5 Template for individual feeding plan ...
Page 219: ...Annex 219 16 4 Basic principle of interval feeding ...
Page 222: ...222 Annex ...