Saffire PRO 26 i/o
User Guide
21
Changes to SaffireControl PRO at
higher sample rates – Disabling ADATs
At higher sample rates, SaffireControl PRO’s functionality and i/o is limited. This can be optimised by disabling the ADAT ports, if
they are not in use. ADAT ports are disabled in the Hardware menu of SaffireControl PRO as follows:
The following outlines the changes to SaffireControl PRO and i/o at different sample rates by detailing 6 modes described below.
Note: The Audio MIDI setup cannot be used to switch to higher sample rates. This must be done using SaffireControl PRO.
Mode 1: 44.1/48kHz Default mode
I/O – 8 Analogue, 2 S/PDIF, 16 ADAT (Total 52)
SaffireControl PRO – Full control
Mode 2: 44.1/48kHz ADAT I/O disabled
I/O – 8 Analogue, 2 S/PDIF (Total 20)
SaffireControl PRO – Full control but no ADATs
The control panel will look exactly the same as for mode No. 1 except the fader bank selector tabs will be greyed out for
the ADAT inputs as they do not operate in this mode.
ADAT ports
enabled/disabled switch
Summary of Contents for Saffire Pro 26 I/O
Page 1: ...User Guide FA0110 01 E OE ...