INSTALLATION INSTRUCTIONS

All instructions must be handed to the user for safekeeping.

Revision A - 05/07

Country(s) of destination - GB/IE

MUSE

MODEL : P23

WALL MOUNTED FLUELESS GAS FIRE

Focal Point Fires plc, Christchurch, Dorset BH23 2BT

Tel: 01202 499330     Fax: 01202 499326

www.focalpointfires.co.uk

e-mail: [email protected]

It is the LAW that all gas appliances and fittings are installed by a competent person (such as a CORGI registered fitter) and in

accordance with the Gas Safety (Installation and Use) Regulations 1998.

©

2007 Focal Point Fires plc.

Summary of Contents for MUSE P23

Page 1: ...FIRE Focal Point Fires plc Christchurch Dorset BH23 2BT Tel 01202 499330 Fax 01202 499326 www focalpointfires co uk e mail sales focalpointfires co uk It is the LAW that all gas appliances and fitting...

Page 2: ...be installed in a correctly sized room see section 3 1 and the correct purpose provided ventilation must be pro vided see section 4 1 It should be noted that heaters create warm air currents These cur...

Page 3: ...nt spaces but these spaces must not be separated by a door To calculate a room size in cubic metres m3 divide the room volume in cubic feet ft3 by 35 3 SITE REQUIREMENTS This appliance is designed to...

Page 4: ...liance The appliance is designed to be wall mounted alone and not in conjunction with any type of combustible fire surround No combustible shelves should be positioned on the wall above the appliance...

Page 5: ...late GAS SUPPLY ROUTES There are four possible entry points for the gas supply pipework to enter the appliance firebox These entry points are knock out type holes Non concealed gas connections may be...

Page 6: ...alignment of the appliance with a spirit level as small adjustments can still be made if necessary When this has been checked tighten all four fixing screws fully To access the upper fixing screws in...

Page 7: ...ircumstances the piezo electric spark fails the pilot cannot be lit manually SETTING PRESSURE The pressure test point is located on the left hand side of the appliance on the main burner pipe next to...

Page 8: ...e from the gas supply Ensure that the fire is fully cold before attempting service A suggested proce dure for servicing is detailed below 1 Lay out the dustsheet and tools 2 Remove the decorative fram...

Page 9: ...can be removed from the base of the pilot unit using two spanners to make cleaning easier Do not damage or try to dismantle the pilot injector The unit is factory set and the only check necessary is...

Page 10: ...r obstruction Faulty thermocouple replace pilot unit Blocked pilot clean out Blocked lint gauze clean Hold control knob in for longer Check control knob does not foul indicator plate If the pilot will...

Page 11: ...ALL MOUNTED FLUELESS GAS FIRE Next Retail Ltd Desford Road Enderby Leicester LE19 4AT Helpline Telephone 0844 844 8999 It is the LAW that all gas appliances and fittings are installed by a competent p...

Page 12: ...ombustion monitoring system ODS DO NOT burn any foreign material on this fire Under no circumstances shall the appliance be used if the glass front door or panel has been removed damaged or is open DO...

Page 13: ...ce It should be established that any mirrors or picture frames etc to be positioned on the wall above the appliance are able to withstand prolonged exposure to moderate heat and moisture before procee...

Page 14: ...m and removal of the draught should resolve this The appliance can then be re lit in accordance with the previous section If pilot disturbance is not the cause then the ODS safety system may be in ope...