background image

INSTALLATION & USER INSTRUCTIONS

MODELS COVERED BY THESE INSTRUCTIONS

L23S MIDNIGHT NG
L23S PORTOBELLO NG
L30S VESUVIUS NG
L23S MIDNIGHT LPG
L23S PORTOBELLO LPG

WALL MOUNTED HIGH EFFICIENCY GAS FIRE

GB IE

All instructions must be handed to the user for

safekeeping. The products covered by this booklet

are protected under patent GB2275331C.

Please note : Except where otherwise stated, all rights, including copyright

in the text, images and layout of this booklet is owned by Focal Point Fires

plc.  You are not permitted to copy or adapt any of the content without

the prior written permission of Focal Point Fires plc. 

Revision D - 11/13

IN THE UK ALWAYS USE A GAS SAFE REGISTERED ENGINEER TO INSTALL, REPAIR OR SERVICE THIS APPLIANCE

'

2013 Focal Point Fires plc.

1

Focal Point Fires plc.

Christchurch, Dorset BH23 2BT

Tel: 01202 499330     

Fax: 01202 499326

www.focalpointfires.co.uk

e : [email protected]

L23S MIDNIGHT

L23S PORTOBELLO

L30S VESUVIUS

Summary of Contents for L23S MIDNIGHT

Page 1: ...rwise stated all rights including copyright in the text images and layout of this booklet is owned by Focal Point Fires plc You are not permitted to copy or adapt any of the content without the prior...

Page 2: ...t only and should not be used in a room without some form of background heating present If the appliance is used in a room as the sole source of heat then condensation may occur on colder surfaces wit...

Page 3: ...rooms The appliance is designed to be versa tile and as such will operate correctly when exposed to normal gentle draughts experienced within the home It is not recom mended however that the appliance...

Page 4: ...may cause cracking along the joint line If the appliance is to be mounted on a dry lined wall or a timber framed construction wall then the integrity and ability of the wall to carry the weight of the...

Page 5: ...on a vertical surface Avoid sloped surfaces Installation onto anything other than a vertical wall may result in fire damage or injury If the appliance is to be mounted on the inner leaf of a conventio...

Page 6: ...s before repeating the ignition procedure To achieve the HIGH setting push the control knob in slightly and continue turning fully anti clockwise to the high position The main burner should light afte...

Page 7: ...well ventilated with all windows and doors open during this period During this period the appliance may cause smoke alarms to sound If this happens reset the alarms but do not remove the batteries Rec...

Page 8: ...s time the catalysts should be replaced If there are any deposits of dirt or soot on the catalyst they should be cleaned with a soft brush and a vacuum cleaner If removed for cleaning ensure the seals...

Page 9: ...re is a draft Fire is too close the an air vent Fire is sited on disused chimney breast which has not been adequately sealed up Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughl...

Page 10: ...efects or obstructions that may prevent the satisfactory flow of combustion products The expected life of the catalyst is in excess of 11 000 hours 10 years of normal use After this time the catalyst...

Page 11: ...ed as a secondary source of heat only and should not be used in a room without some form of background heating present If the appliance is used in a room as the sole source of heat then condensation m...

Page 12: ...F730075 Pilot assembly LPG models SIT OP9286 F730086 Gas valve TRAY106 Burner unit L23S Natural gas models TRAY113 Burner unit L23S LPG models TRAY105 Burner unit L30S Natural gas models F780079 Catal...

Reviews: