![FNM HPE 110 Installation Manual Download Page 41](http://html1.mh-extra.com/html/fnm/hpe-110/hpe-110_installation-manual_2313270041.webp)
FNM® Series HPE – Installation Manual – 37
6.7.1
Trim angle sensor connection
The trim angle sensor must be connected:
1.
Signal: connect the additional orange-blue wire labelled
"TRIM SENDER" to the extension cable, near the ECU.
2.
Ground: lead to a ground point of the electrical system,
possibly near the battery.
In the case of Mercruiser Bravo® stern drive connect the
sensor only to the instrument wiring, excluding other devices.
Figure 48 - "TRIM SENDER" Mercruiser Bravo® stern drive positioned
to the right, equipped with a male and a female connector.
Do not confuse the trim angle sensor, which shows
on it the words "TRIM SENDER", with limit switches
for the limit of the trim stroke, referred to as "LIMIT
SWITCH"
Sensor Type
Order code
Trim+Limit Switch (for Mercruiser Bravo® stern
drive)
4.024.001.1
For the proper operation of the trim sensor, perform all the
operations indicated in chapter 6.9 – Calibration of trim and
fuel level signals on the CANBUS instrument on page 37.
6.7.2
Connecting the trim/trailer control with
Mercruiser® mechanical throttle
The connection of the trim/trailer control to the Mercruiser®
mechanical throttle is not covered by this manual. For
information on connecting, refer to the installation manuals of
the drive and the Mercruiser® mechanical throttle.
The drive has a limit switch for the "LIMIT SWITCH" trim
operation that must not be confused with the "TRIM SENDER"
sensor. The limit switch, shoe in the following figure, is
connected to the throttle to control the trim.
Figure 49 - Mercruiser Bravo® stern drive "LIMIT SWITCH" Trim
positioned to the left, with two male connectors.
The order codes of the Mercruiser® throttle elements are the
following:
Throttle type
Throttle order
code
TRIM command electric
cable
Single wall-
mounted
2.018.308.1
2.018.311.1
Single on
dashboard
2.018.341.1
Double on
dashboard
2.018.304.1
2.018.342.1
Only trim panel
-
1.049.017.1
(including panel)
6.7.3
Connecting the trim/trailer control with
Flexball® electronic throttle
Use the prearranged cable contained in the box of the
electronic throttle, and follow the guidelines on the Flexball®
electronic throttle manufacturer's manual.
In case of Mercruiser Bravo® stern drive, connect
the LIMIT SWITCH of the drive, equipped with two
round female fastom connectors to the throttle
wiring.
6.8
Fuel level in the tank sensor (if present)
Connect the fuel level float as follows:
1.
Signal: connect the additional pink wire labelled "FUEL
LEVEL" on the extension cable, near the ECU.
2.
Ground: lead to a ground point of the electrical system,
possibly near the battery.
It is possible to use any type of resistive level sensor
compatible with the EU (0 to 180Ω) or USA (240 ÷ 33Ω)
standards.