background image

 

TOUCH-SAFE FAN ASSISTED

HEATERS

User Manual

WARNING

Read instructions before installing or operating 
this device. Keep for future reference.
Installation should be done by qualified personnel 
following all National, State, & Local Codes
Be sure to remove all power supplying this 
equipment before connecting or disconnecting 
wiring.
Only install the heater inside an electrical 
enclosure, in vertical position with cables facing 
down, and in the bottom half of cabinet.
A disconnection system must be installed upstream 
of the heater.
Protection against access to live parts must be 
covered by the installer.
Don’t  install  in  ambient conditions with  excessive 
moisture and dirt.
Installation  position  must  be  selected  to  ensure 
good  ventilation.  Take  care  that  any  internal
components of enclosure do not obstruct air flow.
Do not mount near easily flammable materials.

 

Follow all technical data shown in this manual.

Customer  is  solely  responsible  for  validating  application,  operation, 
maintenance,  and  code  compliance  and  other  information  and  data 
relating  to  the  installation,  operation,  safety,  and  maintenance  of  all 
components. There is no guarantee that this information is suitable for 
your application, nor is there any manufacturer/supplier assumption of 
responsibility for your product design, installation, testing, or operation. 
Information herein is provided “as is” with no guarantee of any kind. 
Every attempt has been made to ensure the accuracy and reliability of 
the information provided in this document.

 

 

 

 

1 - DESCRIPTION

GENERAL DESCRIPTION

Fan assisted heaters are optimized to avoid 
condensation or provide a minimum temperature 
inside closed cabinets.

Model

Heating 

Capacity 

[W] 

Power 

Supply  

Current 

Usage 

[A] 

FTM-HT150-TSFA-1 

150 

120VAC 

1.3 

FTM-HT150-TSFA-2

150

240VAC

0.65

FTM-HT250-TSFA-1 

250 

120VAC 

2.2 

FTM-HT250-TSFA-2 

250 

240VAC 

1.1 

FTM-HT300-TSFA-1 

300 

120VAC 

2.6 

FTM-HT300-TSFA-2 

300 

240VAC 

1.3 

FTM-HT400-TSFA-1

400

120VAC

4.5

FTM-HT400-TSFA-2 

400 

240VAC 

1.75 

2 - DIN RAIL INSTALLATION

WARNING

Before installation, switch off the power 
supply.
Keep a thermal safety clearance of 300
mm from the air outlet, 100mm from air 
inlet, and 20mm from the sides.

E351779 

Reviews: