21
Operating instructions - digital oval gear meter and pulse meter
US
6
PRESS RESET SHORTLY / SEVERAL SECS
Value indicated will change as indicated by arrow.:
■
■
One increment per each time TOTAL is pressed..
■
■
Continuously if TOTAL is held down. Display will ‚roll‘
more quickly if button is held permanently.
If you overshoot, go back to point 5 and repeat.
7
PRESS RESET SEVERAL SECS
This is how the meter ‚knows‘ that calibration is now complete.
Before you press this button, be absolutely sure the
value indicated is the value you wanted to set.
8
NO OPERATION
After the following calculation the new USER K FACTOR will
be displayed a few secs. Next, the meter will re-start. Finally,
the meter will be back in default standby mode.
PLEASE NOTE: From now on, the new value set will be
used as the new valid K Factor and will remain even after
replacement of batteries.
9
NO OPERATION
The meter stores the new K Factor for operation and is now
ready for serious operation using the newly set USER K
FACTOR.
9. Configuration of the meter
The oval gear meter has a menu to assist users in the selection of the main unit of measure: quarters (QTS),
pints (PTS), litres (L), gallons (GAL).
Combining partial-volume and total-volume units is possible as shown in the following table:
Combination no.
Unit Register of
partial amounts
Unit Register of
total amounts
1
litres (L)
litres (L)
2
gallons (GAL)
gallons (GAL)
3
quarters (QTS)
gallons (GAL)
4
pints ( (PTS)
gallons (GAL)
This is how you select any of the combinations proposed:
Wait until the meter is in default standby mode. Simultaneously press TOTAL and RESET until the
display shows the word „UNIT“ displaying the valid unit being used at present (in our example: litres/
litres).