Operating Manual CMGZ100 

Analog Tension Controller 

 
 

Version 2.01  04/02  fg 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Diese Bedienungsanleitung ist auch in deutsch erhältlich. 

Bitte kontaktieren Sie die Vertretung im zuständigen Land. 

 
 

This operation manual is also available in german. 

Please contact your local representative. 

 
 
 
 
 
 

© by FMS Force Measuring Systems AG, CH-8154 Oberglatt – All Rights reserved.. 

Summary of Contents for CMGZ100

Page 1: ...ese Bedienungsanleitung ist auch in deutsch erh ltlich Bitte kontaktieren Sie die Vertretung im zust ndigen Land This operation manual is also available in german Please contact your local representat...

Page 2: ...in case of malfunction the person responsible for system design has to establish specific safety procedures such as emergency stop ciruits etc Caution Improper handling may damage the fragile electro...

Page 3: ...line speed 5 3 Wiring diagram 6 4 View of the setting elements 6 5 Operating the strain gauge amplifier 7 5 1 Calibrating the strain gauge amplifier 7 5 2 Lowpass filter 7 5 3 Setting the limit switc...

Page 4: ...released over a digital input that is operated with 24VDC or AC The Tension Controller also has also a minimum and a maximum limit switch with relay outputs The pcb is built to European standard size...

Page 5: ...the threshold is overrun the appropriate front mounted LED lights up and a relay switches on 24V 0 5A The thresholds are being set with front mounted 10 turn potentiometers R3 ad R4 The threshold valu...

Page 6: ...ensors are connected using 2x2x0 75mm2 AWG 18 shielded twisted pair cable With cable length below 15m 2x2x0 25mm2 AWG 23 is also suitable The shield must be connected only to the Tension Controller si...

Page 7: ...r similar The adjustment of the cutoff frequency is done by means of a non polarized capacitor using the following table Setting the cutoff frequency The corresponding capacitor is chosen with the fol...

Page 8: ...0k as standard giving 10 The resistor value in k gives the percentage With no line speed the Jumper has to be in position X24 to give exact 100 6 3 Internal external tension reference To use the inter...

Page 9: ...short circuit proof Controller release isolated input 12 30V AC or DC if input is inactive integral part and output are set to zero Limit switch 1 Minimum Adjustable with potentiometer corresponding t...

Page 10: ...Operating Manual CMGZ100 10...

Page 11: ...Operating Manual CMGZ100 11...

Page 12: ...MS Italy Via Baranzate 67 I 20026 Novate Milanese Tel 39 02 39487035 Fax 39 02 39487035 fmsit fms technology com FMS USA Inc 2155 Stonington Ave Suite 119 Hoffman Estates IL 60169 USA Tel 1 847 519 44...