FMA Cellpro Multi4 Manual Download Page 1

20

090126

FMA limited warranty

FMA, Inc. warrants this product to be free of manufacturing defects for the term of one year from the date of pur-
chase.  Should any defects covered by this warranty occur, the product shall be repaired or replaced with a unit of 
equal performance by FMA or an authorized FMA service station.

Limits and exclusions

This warranty may be enforced only by the original purchaser, who uses this product in its original condition as 
purchased, in strict accordance with the product’s instructions.  Units returned for warranty service to an FMA 
service center will be accepted for service when shipped postpaid, with a copy of the original sales receipt or war-
ranty registration form, to the service station designated by FMA.

This warranty does not apply to:

  Consequential or incidental losses resulting from the use of this product.

  Damage resulting from accident, misuse, abuse, neglect, electrical surges, reversed polarity on connectors, 

lightning or other acts of God.

  Damage from failure to follow instructions supplied with the product.

  Damage occurring during shipment of the product either to the customer or from the customer for service 

(claims must be presented to the carrier).

  Damage resulting from repair, adjustment, or any alteration of the product by anyone other than an authorized 

FMA technician.

  Installation or removal charges, or damage caused by improper installation or removal.

Call (301) 668-4280 for more information about service and warranty repairs.

Quick start for the Cellpro Multi4 Charger

Refer to manual for complete operating details.

A.  Connect charger to a 12V to 16V (maximum), 5A power source.

B.  At Welcome screen, press 

Mode

 button to display Preset Menu.

C.  In Preset Menu, press 

Mode

 button to display User Preset for pack you want to charge.

D.  Connect pack to charger.

E.  Press and hold 

Mode

 button.  When you see 

START CHARGE

, release 

Mode

 button.  Display 

briefl y shows 

CHECKING PACK

.

F.  Next screen displays preset’s chemistry and prompts you to verify it is same as pack’s chem-

istry.  This is a safety check.

  If displayed chemistry 

matches

 pack chemistry, press 

Mode

 button to start charging.  Go 

to step G.
 or

  If displayed chemistry 

does not match

 pack chemistry, do nothing.  Screen will time out 

and Preset Menu will be displayed.  Go to step C.

G. During charging:

 Press 

Mode

 button to view charging data screens.

 

To stop charging:

a.  Press and hold 

Mode

 button to see 

STOP CHARGE? >No

.

b. Press 

Mode

 button to see 

STOP CHARGE? >Yes

.  Press and hold 

Mode

 button.

c.  When you see 

CHARGER STOPPED

, press 

Mode

 button to see Preset Menu (step C).

H.  When charging is complete, charger beeps three times repeatedly and displays 

ELAPSED 

[time] / [chemistry] DONE

.  Press 

Mode

 button to review charging data screens.

I.  Disconnect pack from charger.  Display shows 

PACK REMOVED

.

J. Press 

Mode

 button to return to Preset Menu.

Cellpro Multi4 Charger

Model LC04S04A-MC, for use with LiPo, Li-Ion, A123, 
NiCd, NiMH and Lead Acid battery packs

Automatic and manual charge rates at up to 4A with 
overcharge protection and cell balancing (for packs with 
node connectors)

FMA, Inc.

  

  5713 Industry Lane, Suite 50  

  Frederick, MD  21704

Sales: (800) 343-2934  

  Technical: (301) 668-4280  

  www.fmadirect.com

Features

  Simple to operate:  just connect the Cellpro Multi4 Charger between a power source and 

a pack, select a pack-specifi c preset and start charging.  No jumpers, plugs or dials to set!  
Charger automatically determines pack capacity and sets optimal current, then dynamically 
adjusts charge rate as needed.  Manual charge rates up to 4.0A allow for special situations.

  Charges LiPo, Li-Ion, LiFePO4, A123©, LiMn, NiCd, NiMH and Lead Acid chemistries 

(adapters for many node connector types are available from FMA Direct).  Supports both bal-
anced (depending on chemistry) and non-balanced charging (with certain safety limitations).

  Charger holds up to 25 user confi gurable presets (User Presets), optimized for the different 

chemistries, providing charging strategies for most common RC charging needs.  Charger also 
holds up to 50 Library Presets.  When using the free Charge Control Software, the number of 
custom presets is virtually unlimited and will grow over time to meet industry needs.  Replace 
and customize presets to match your battery inventory.

  Charges Lithium (2s to 4s balanced charge, 1s to 2s unbalanced charge) and A123 packs (2s 

to 4s balanced, 1s to 5s unbalanced) in any capacity up to 32Ah.  During balanced charging, 
each cell is charged independently, providing exceptional charging safety and elevating RC 
packs to the safety level of cellphones.  Typical packs of up to 4Ah capacity charge in 50 
minutes or less using charger’s 2C Auto Current Mode.

  Latest technology provides the ultimate in safety—even charges packs having hidden physical 

damage without danger of fi re.  A pack will not charge if individual cell voltages don’t equal 
total pack voltage.

  Cell balancing to 5mV and automatic overcharge protection assure longest pack life.  Auto-

matic temperature monitoring prevents pack overcharging at low ambient temperatures and 
charger damage at high ambient temperatures.

  Multifunction backlit display lets you select presets, replace default presets from a library 

and shows charging data such as individual cell voltages, charge current, supply voltage, and 
amount of charge (mAh) put into pack.  Plus, the unique Fuel display shows percent capacity 
in a pack.

  Charge Control Software (CCS, a free download) allows you to customize, save and load pre-

sets (including charger data displays), and view real-time charging data and graphs.  CCS also 
manages fi rmware updates to keep your charger operating smoothly.

  Operates from any 10–16V DC power source.  Inputs and outputs are protected against re-

verse polarity.

Precautions

  Follow all instructions in this manual to assure safe operation.

  Always watch LiPo packs while they are charging.  Never leave LiPo packs unsupervised 

during charging.

  See additional warning sheets provided with this charger and FMA LiPo packs.

  Follow all guidelines for charging, discharging, handling and storing packs of all kinds.

Summary of Contents for Cellpro Multi4

Page 1: ...and Lead Acid battery packs Automatic and manual charge rates at up to 4A with overcharge protection and cell balancing for packs with node connectors FMA Inc 5713 Industry Lane Suite 50 Frederick MD 21704 Sales 800 343 2934 Technical 301 668 4280 www fmadirect com Features Simple to operate just connect the Cellpro Multi4 Charger between a power source and a pack select a pack specific preset and...

Page 2: ... Node 3 11 1V Cell 2 Node 2 7 4V 4s Pack Cell 1 Node 1 3 7V Cell 3 Cell 2 Node 2 7 4V 3s Pack Cell 1 Node 1 3 7V Pack postive red 7 4V Pack negative blk 0V Pack postive red 11 1V Pack negative blk 0V Cell 2 2s Pack Cell 1 Node 1 3 7V Nominal voltage with respect to pack negative 19 Troubleshooting Operating errors appear as safety codes in the display If possible correct the error If errors contin...

Page 3: ...containing up to 50 presets A Library Preset is like a User Preset except that it must be loaded into the User Preset bank before it can be changed and used for charging see Loading a Library Preset later 1 Connect the charger to a 12V to 16V maximum 5A power source You can connect the pack any time between now and step 4 2 The first screen you will see is the Welcome screen Press and release the ...

Page 4: ... 1s to 4s balanced 1s to 2s unbalanced Lithium Manganese 1s to 4s balanced 1s to 2s unbalanced A123 2s to 4s balanced 1s to 5s unbalanced NiCd 1s to 12s NiMH 1s to 12s 6V and 12V Lead Acid batteries Pack capacity 5mAh to 32Ah charge time limited to maximum of 8 hours Input voltage 10 to 16VDC reverse polarity protected Input current 5A maximum Power conversion 125kHz switcher operating at 90 effic...

Page 5: ...perties tab in the right panel then set options as needed To change charge data screens Click the Screens tab in the right panel then To show or hide a data screen Select Show or Hide as appropriate To change screen order Drag the screen number up or down 4 Click Update Charger or If you don t want to apply the changes click Cancel Note The Charge Control Software performs extensive checks to make...

Page 6: ...button when you see the opera tion you want Tip If you are using the Charge Control Software you can shorten the Preset Menu by hiding User Presets you don t use as well as hiding Empty Presets See Configuring User Presets later in this manual 15 Monitoring charging operations When you start a charge at the charger the CCS opens a dialog that enables you to save the charge graph To save the graph ...

Page 7: ... Follow onscreen instructions to install the driver for your PC interface FUIM2 or FUIM3 Exit and relaunch the CCS 2 Plug the FUIM2 or FUIM3 s 3 pin connector into the jack on the charger s left side The black wire should be toward the top of the charger s panel 3 Plug the FUIM 2 or FUIM3 s USB connector into your computer 4 Apply power to the charger 5 Waiting to Start above the tabs confirms tha...

Page 8: ...eset similar in all regards to Preset 1 above but with Fuel Table optimized for REVOLECTRIX Black Label batteries If used with other brands the Fuel Gauge readout may not be accurate and AUTO charge rate may be higher or lower than expected Default charge rate setting is 1C AUTO 8 LiPo REVO Black Faster Charge Brand Specific LiPo preset similar in all regards to Preset 2 above but with Fuel Table ...

Page 9: ...rge rates include 1C 2C 3C AUTO or 0 25A to 4 0A manual Optimization is for the most accurate charging with termination settings of C 20 and max of 30 min timeout for C V mode This preset requires that every cell in the battery is charged to exactly 100 This preset may also be used for LiFePO4 type batteries which have similar charge characteristics When using LiFePO4 batteries Fuel Gauge readout ...

Page 10: ...library 11 Loading a Library Preset The Multi4 Charger is equipped with 50 Library Presets A Library Preset which you can t change is a starting point for creating your own User Preset which you can change FMA configures Library Presets with optimal charge characteristics for a variety of battery chemistries and charging strategies You can replace an existing User Preset with a Library Preset or i...

Reviews: