OPERATIONAL TEST
5G Paint Mixer Instruction Manual
17
OPERATIONAL
TEST
1. Turn to “BASIC OPERATION” on page 19 to be sure you understand
how to operate this mixer before beginning this test.
2. Plug in the mixer.
3. To perform this test, use two one-gallon containers, followed by a five-
gallon container, and perform these steps:
•
With the one-gallon containers in position on the table, set the
TIMER to its minimum value.
•
Twist the EMERGENCY STOP to release it.
•
Depress the POWER switch.
•
With one hand on the EMERGENCY STOP, depress the START
switch. The unit should cycle automatically--clamping down and
starting the shake cycle with a smooth, vibration-free movement.
4. If vibrations are noticed, immediately press down the EMERGENCY
STOP switch.
•
Mild vibrations may occur because the unit is not properly leveled.
Try slipping a piece of paper under each of the four (4) adjustable
feet. If the paper easily slides under a foot (feet), then the mixer is
not solidly contacting the floor. Level as necessary.
•
Severe or persistent vibrations may be caused by a variety of
problems. Check to make sure that the struts are moving freely. If
they are, then contact a qualified service technician or Customer
Service at Fluid Management for assistance before continuing to
operate the mixer.
5. Repeat the above steps using a 5-gallon container.
6. When the unit is operating smoothly, replace and secure the top cover
and upper rear cabinet with the screws.
7. Your high speed paint mixer is now ready for operation. Please read the
next two sections to familiarize yourself with the machine and how to
operate it safely.