30m CORRIDOR  WIRELESS PIR

The  4193-GB  is  a  Class  3  wireless    PIR,  for  operation  with  4000  series  wireless  control  panels.
This unit employs the FM corridor lens.

INHIBIT

    To  prevent  repeated transmissions  and  resultant  battery  drain,  the PIR  incorporates  a  2

minute  inhibit  timer.    When  movement  is  detected  the  alarm  is  transmitted  and  then  further
transmissions are inhibited for 2 minutes or until the PIR has seen no movement for two minutes.

PULSE  COUNT

      The  recommended  setting  for  a  corridor  is  no  pulse  count.  (Link  3  should  be

fitted)

RECOMMENDED BATTERIES

  Two AA size Alkaline batteries are required, Eveready or Duracell

are recommended. (Available from FM Electronics)

MOUNTING

    Mount  the  detector  so  that  anyone  entering  the  area  passes  across  the  detection

beams. See diagram below for optional mounting heights.

TILT  ADJUSTMENT

    The  Lens  must  be  set  precisely  central,  to  prevent  the  main  beams  from

looking down.
If  the  ground  is  sloping  the  detector  should  be  set  to  the  same  slope  angle.    This  can  be
accomplished by loosening the two lens fixing screws and sliding the lens fully up to tilt upwards 4
degrees or lens fully down to tilt the beams downwards 4 degrees.
(Refer to the separate graphs overleaf if the ground is sloping.)

4193-GB

WALK TEST BUTTON

    has two functions:

1.

When pressed for one second sends a Learn transmission to the control panel,
enabling the device to be learned in and RSSI measurements taken.

2.  Provides a user walk test facility for two minutes.

Press for walk
test
& Learn
transmission

PROGRAM  LINKS

NO LINKS FITTED  -  

Pulse count =2

LINK 3 FITTED

-

No pulse count

LINK 2 FITTED

-

Pulse count = 4

LINK 1 FITTED

-

Overrides the 2 minute inhibit.  With this link fitted the PIR will
transmit again after 2 minutes with continuous movement
present.  Link 1 s unaffected by links two or three

ADDING A DETECTOR TO THE 4000 SERIES CONTROL PANEL

1.  Connect the batteries. The detector will take approx. 5 minutes to settle. So although

you can program it, the PIR will not detect movement for the initial 5 minutes & until 2
or more minutes of no movement have been detected in normal operation.

2.  Enter the engineers program by keying in the engineers code (default = 4679). (The

alarm LED will flash slowly to indicate that you are in engineer mode).

3.  Key in the number of the zone to which the detector is to be allocated. i.e.

FM4000E, 01 for zone 1.  08 for zone 8.
FM4000X, 011 for zone1 device1.   012 for zone1 device2.

4.  Press the walk test button. The control panel will bleep twice and a zone LED will

illuminate. The zone LED’s indicate the number of devices programmed onto the zone.

5.  Press the Full Set key to accept, check the signal strength (see the control panel

instructions for details) & then mount the device in  correct position.

6.  Exit Engineering mode by pressing 48 on the control panel.

Lens adjust
screws

Forest Vale Road, Cinderford, Gloucestershire, GL14 2PH
Tel: ( 01594 ) 827070   Fax:  ( 01594 ) 827066
www.fmelectronics.co.uk

Program links

CI-221 ISSUE 1

2          4        6          8       10       12        14       16      18       20      22      24       26        28       30                   

2          4        6          8       10       12        14       16      18       20      22      24       26        28       30                 

2          4        6          8       10       12        14       16      18       20      22      24       26        28       30                   

Lens central.   Mounting height 1.8 m     (Angle -4 degrees)

Lens fully up.    Mounting height 1.0 to 1.5m    (Angle 0 degrees)

Lens fully  down.    Mounting height 1.8 m    (Angle -8 degrees)

For this configuration the lower beams may be masked off 

PDF created with pdfFactory trial version 

www.pdffactory.com

Reviews: