background image

27263 - A.1

Operator’s Manual / assembly instructions

Translation of the original

GB

XANAS

®

 Electrical Installation

Summary of Contents for XANAS 1.5

Page 1: ...27263 A 1 Operator s Manual assembly instructions Translation of the original GB XANAS Electrical Installation...

Page 2: ...8 3 3 1 Control unit 8 3 3 2 Control box NT 9 3 3 3 Pump type WK 10 3 3 4 Connection diagrams Manually controlled design 11 3 3 5 Operation Manually controlled design 12 3 4 Sensor controlled design m...

Page 3: ...et including personnel retained to assemble the system The rating plate indicates the series and frame size the most important operating data and the factory number If additional information is requir...

Page 4: ...also be emptied The operator must ensure that the operator s manual is always available for operating personnel the instructions in the operator s manual are observed the counter current system is st...

Page 5: ...to observe the information provided in these operator s manual all claims under warranty shall be void The manufacturer cannot accept any liability for resulting consequential damages Attention Failur...

Page 6: ...U XANAS 4 0 FU Output 1 5 kW 1 5 kW 1 9 kW 1 9 kW 3 0 kW 4 0 kW Mains voltage 3 400 V 1 230 V 3 400 V 1 230 V 3 400 V 3 400 V Mains frequency 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz Motor voltage Y 400 V...

Page 7: ...nts a Manually controlled design b Sensor controlled design 3 2 1 Manually controlled design 3 2 2 Sensor controlled design The two design variants are presented separately from each other below Contr...

Page 8: ...Functions White Switching contact S1 Brown Switching contact 24V Grey LED1 Yellow LED2 Green LED3 Effect of switching Pulse activated one time Electrical function normally open N O contact Electrical...

Page 9: ...als for control and feedback contacts Bus connection Terminal compartment disconnection Fault message Current monitoring 1 Phase and 3 Phase Operation Run time limit time relay function Control box NT...

Page 10: ...or dinated in the device kit Operator s Manual 27220 Centrifugal Pump WK applies General information with data sheet for pump WK Safety Instructions Transport and storage Electrical connection of the...

Page 11: ...ical Installation Version 27263 A 1 Schmalenberger GmbH Co KG D 72072 T bingen Germany 3 3 4 Connection diagrams Manually controlled design Range of the connection terminals 5 Electrical power source...

Page 12: ...H Co KG D 72072 T bingen Germany 3 3 5 Operation Manually controlled design Switching On Off Pressing the ON OFF button turns the system on or off The button is always lit and flashes to provide visua...

Page 13: ...ion Activation via 1 x sensor button lit 2 x sensor buttons unlit Sensor button connection cable 9 wire special cable Standard cable length 2m Colour coded DIN 47100 External diameter 6 3mm Wire cross...

Page 14: ...ying the cables Safety isolation For reasons of electrical safety the sensor button must without exception be operated via safety isolation such as a control box item no 61405 or directly on the NT sw...

Page 15: ...ection function The mains power connection for the FU must be designed according to the information in the INVEOR Operator s Man ual KOSTAL Operator s Manual 27220 Centrifugal Pump WK applies General...

Page 16: ...hange between the two operating modes with DigIn4 Operating mode 1 Internal potentiometer Operating mode 2 Analog control Commissioning function XANAS function Manual speed setting via rotary potenti...

Page 17: ...ometer on the FU 3 4 4 3 Analog control operating mode As terminals for XANAS function The FU does not start up until the hardware enable En HW is set At the time of delivery the hardware enable En HW...

Page 18: ...on Relay 1 potential free change DigiOUT1 Switches with Operation Relay 2 potential free change DigiOUT2 For additional terminal assignments please see the INVEOR Operator s Manual Section 3 3 4 Contr...

Page 19: ...arting voltage 4V control range 4 5 6 7 8 9 10V Dout4 ON when AOUT is active ON when AOUT 0V and non active enable Air valve control If AOUT is active a pulse combination to S2 2 pulses within 0 5sec...

Page 20: ...onnected box when the lit ON OFF button indicates this visually by flashing 2 MODE1 active via rotary switch Measurable signals OFF Aout 0V Dout4 0V ON Start status AOUT 4 5 6 7 8 9 10V Dout4 24V Pres...

Page 21: ...l feedback Pressing the keys increases or reduces the corresponding amount The lit sensor but ton flashes to provide visual feedback When the maximum or minimum quantity is reached the button flashes...

Page 22: ...y 3 5 Installation instructions for sensor button and control unit FU motor Converter box 3 0 Safety isolation Line length 2m standard extendible up to 30m Safety isolation integrated Control box NT S...

Page 23: ...23 XANAS Electrical Installation Version 27263 A 1 Schmalenberger GmbH Co KG D 72072 T bingen Germany...

Page 24: ...rger GmbH Co KG Phone 49 0 7071 70 08 0 Str mungstechnologie Fax 49 0 7071 70 08 10 Im Schelmen 9 11 Internet www fluvo de D 72072 T bingen Germany E mail info schmalenberger de 2018 Schmalenberger Gm...

Reviews: