Page 1: ...GB 27213 E 1 NTG700 rondo...

Page 2: ......

Page 3: ...general 12 4 7 Installation kit Installation Pre fabricated pool 13 4 8 Installation kit Installation Wood liner pool 14 4 9 Pump Kit Installation 15 4 10 Mounting the face plate assembly 17 5 Electri...

Page 4: ...unit nor parts thereof must be used in other systems You are expressly directed to use it only in accordance with these instructions The counter current system must not be operated beyond the paramete...

Page 5: ...of the motor and the water 5 If the counter current system is built into a pump pit then it must be ensured that there is enough ventilation for cooling the motor and enough drainage facility for lea...

Page 6: ...ower 1 5 kW 1 5 kW 1 9 kW 1 9 kW 3 0 kW Voltage V 400 Y 230 D 230 D 400 Y 230 D 230 D 400 Y 230 D Frequency 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz Current 2 86 A 9 5 A 3 6 A 11 5 A 5 75 A RPM 2840 Upm 2790 Upm...

Page 7: ...2 fig 3 I Pump kit The pump kit consists of 1 Pump assembly Item 01 2 Suction hose Item 16 3 Pressure hose Item 13 The pump kit is always identical no matter what sort of pool it is intended for III A...

Page 8: ...is concreted into the concrete wall of the pool For details regarding installation please see section 4 III Installation kit for concrete liner pool The installation kit consists of 1 Housing Item K...

Page 9: ...allation kit for wood liner pool The installation kit consists of 1 Housing Item K 2 Clamp ring Item 22 3 Clamp gasket Item 39 4 Washer Item 68 5 Hold ring Item 67 6 Mounting screws Items 63 74 7 Nuts...

Page 10: ...33 must not exceed 1m 4 3 Installation Preparations Concrete pool Tailor the installation kit Place the installation kit on the formwork board and transfer the bore holes Bore the holes into the pool...

Page 11: ...oard Pb Pool side formwork board 1 Pressure pipe DN 50 2 Suction pipe DN 65 3 Air supply to the non return air valve fig 13 Boring diagram Tailor the installation kit Apply the cavity 205 and the moun...

Page 12: ...allation kit Apply the cavity 260 and the mounting holes 12 to the pool wall Warning Risk of damage The hold ring 68 must be used as a template Take note of the asymmetrical position of the holes fig...

Page 13: ...Pre fabricated pool Mount the clamp ring 22 with the clamp gasket 39 and the hold ring 62 to the pool wall The sealing contact faces must be clean and smooth Then mount the housing K on the clamp rin...

Page 14: ...and the clamp gasket 39 together with the clamp ring 22 and cut out the liner L Then mount the installation kit 92 on the clamp ring 22 with the screws 74 See also detail X in fig 18 fig 17 fig 18 Det...

Page 15: ...of the pipework Warning 1 Do not use any vibration dampers between the pump and the base frame 2 If the pipework R to the pump is longer than 6 m then the nominal width must be increased Suction side...

Page 16: ...ter S in the face plate assembly and the aerial 33 as short as possible fig 21 01 Motor 12 1 Air pipe clamp 12 3 Air pipe clamp 13 Hose line pressure side 16 Hose line suction side Warning Make sure t...

Page 17: ...ll or similar In the case of a ground level overflow place the non return air valve 28 in the duct see fig 23 detail B 4 10 Mounting the face plate assembly Figure 24 shows the rear of the face plate...

Page 18: ...C Place the clamp gasket 32 between the instal lation housing 99 and the liner L and screw the clamp ring 72 to the installation housing 99 using the screws 74 The sealing contact faces must be clean...

Page 19: ...o one another Fasten to the clamp ring 22 with the screws 90 3 4 10 4 Face plate assembly Installation Wood liner pool Put on the face plate assembly 35 this allows the pressure connection D and air c...

Page 20: ...mi nal box lid is closed 5 1 1 Direction of rotation check In the case of 3 motors the direction of rotation must be the same as the direction of ro tation arrow on the blower cover of the counter cur...

Page 21: ...Germany 5 1 2 Additional motor equipment Warning If particular control devices are to be used e g in connection with the installa tion of the counter current swimming system in a process engineering f...

Page 22: ...16A passive Connecting cable e g HO7RNF fig 29 Schematic AC circuit diagram for radio control fig 30 Schematic AC circuit diagram for external control fig 31 Schematic AC circuit diagram for pneumati...

Page 23: ...ns can be found on the motor and pump type plates Warning The manufacturer must be consulted if the mains voltage is 230 V for 3 AC fig 32 Schematic 3 AC circuit dia gram for radio control fig 33 Sche...

Page 24: ...nuous operation see section5 5 Setting the operating time Water supply control By turning the knob KW clockwise the water supply decreases anti clockwise it increa ses Air supply control Air bubble ba...

Page 25: ...press the sliding sleeve V against the nozzle D and pull back on the hose coupling F That cau ses the hose coupling to be locked in place Detaching the massage set Switch off the counter current swim...

Page 26: ...ack in again with a new O ring 07 When restarting please observe the instructions in section 6 fig 38 Warning Risk of damage If there is a risk of freezing then the facility must be made winterproof O...

Page 27: ...r counter current swimming sy stem When ordering spare parts please do not fail to give us the following important information Pump serial number and type description or alternatively the motor serial...

Page 28: ...lgeh use Carter spirale Spiral housing 1 04 21140 Gleitringdichtung Joint M chanique Mechanical seal 1 05 51066 Unterlegscheibe Rondelle Distance washer 1 06 1 51047 Laufrad Turbine Impeller 1 1 5 kW...

Page 29: ...te Face plate assembly 1 36 65032 Drehgriff Luftreg Bouton r gul air Air regul knob 1 37 65033 Drehgriff Wasserreg Bouton r gul d bit Water flow knob 1 38 56232 D sengeh use T te de buse Face plate 1...

Page 30: ...8 1 92324 Einbauelemente Fittings Fittings 1 83 12392 Unterlegscheibe Rondelle Distance washer 8 A8 84 12181 Sechskantmutter crou six pans Hexagon nut 8 M8 85 12392 Unterlegscheibe Rondelle Distance w...

Page 31: ...96 26 01 03 06 07 08 07 11 09 10 12 13 12 20 incl 29 07 11 93 83 14 15 17 16 15 04 05 35 55 42 54 47 46 45 44 43 2 53 50 49 48 51 50 43 1 87 88 86 61 75 2 19 41 40 36 38 37 90 1 25 65 33 23 24 31 21...

Page 32: ...26 01 03 06 07 08 07 11 09 10 12 13 12 20 incl 29 07 11 93 83 14 15 17 16 15 04 05 34 74 72 35 55 42 54 47 46 45 44 43 53 50 49 48 51 50 43 1 87 88 86 61 75 2 19 41 40 36 38 37 90 2 25 65 33 23 24 31...

Page 33: ...arts List 8381 97 98 96 95 01 03 06 07 08 07 11 09 10 12 13 12 91 incl 77 07 11 93 83 14 15 17 16 15 04 05 77 22 39 62 83 26 74 48 43 1 35 55 42 54 47 46 45 44 43 53 50 49 51 50 87 88 86 61 75 2 19 41...

Page 34: ...ist 97 98 96 95 01 03 06 07 08 07 11 09 10 12 13 12 92 incl 78 29 07 11 93 83 14 15 17 16 15 04 05 39 74 22 63 67 68 64 65 84 85 78 48 43 1 35 55 42 54 47 46 45 44 43 53 50 49 51 50 87 88 86 61 75 2 1...

Page 35: ...Schmalenberger GmbH Co KG D 72072 T bingen Germany...

Page 36: ...08 0 Str mungstechnologie Telefax 49 0 7071 70 08 10 Im Schelmen 9 11 Internet www fluvo de D 72072 T bingen Germany E Mail info schmalenberger de 2009 Schmalenberger GmbH Co KG All rights reserved Th...