Stand Fitting 5/8”
G6FLT057
2 Safety Cables:
1 for barndoor
1 for fixture
G6FLT059
Barndoors - 8 Blades
G6LED121
Filter Holder
G6LED096
C-Clamp
G6FLT262
G6LED173
G6LED182
(Pole Operated)
VegaLux 200
® HP
Tungsten StudioLED
FRESNEL
®
3100K
2.5
120VAC
G6LED174
G6LED183
(Pole Operated)
VegaLux 200
® HP
Daylight StudioLED
FRESNEL
®
5700K
90-240V
MECHANICAL CHARACTERISTICS
MODEL
DIMENSIONS
WEIGHT
ELECTRICAL MEASUREMENTS
MAXIMUM VALUES
Peak Current [A]
Current [A]
Power [W]
Voltage [V]
11.22”x 11.29”x 18.46”
30.7 cm x 28.7 cm x 46.9 cm
7.28 kg
16.04 lb
1.64
197
VegaLux 200
®
HP
StudioLED FRESNEL
®
is not a color mixing LED system.
There are dedicated Tungsten and Daylight color models.
Tungsten
Code:
G6LED173
Code Pole Operated:
G6LED182
Color Temperature:
3100K
Color Rendering Index (CRI):
+93
Weight:
16.04 lb
(7.28 kg
)
Specs & Performance: Daylight & Tungsten Models
Daylight
Code:
G6LED174
Code Pole Operated:
G6LED183
Color Temperature:
5700K
Color Rendering Index (CRI):
+93
Weight:
16.04 lb
(7.28 kg
)
Fuses & Power Consumption
Note -
Most electrical equipment briefly consumes a higher amount of electrical
current during startup (ignition). Consult the chart below to confirm that your
electrical wiring is sufficient for the fixtures used. All fuses must be rated at
250VAC. VegaLux 200
®
HP
StudioLED FRESNEL
®
auto-set from 90-240 VAC.
Each fixture comes with:
Optional Accessories:
Display & Buttons
Functions
The VegaLux 200
®
HP
StudioLED FRESNEL
®
has one display, and four (4) buttons
that allow to perform various functions.
Display
Handle
Button Function
“MENU”
AC input connector
90-240 VAC
DMX input signal
connector “DMX IN”
Power ON/OFF
Fuse-holder
Safety Cable
Holder
Button Function
“ENTER”
Button Function
“UP”
AC output connector
90-240 VAC
DMX output signal
connector “DMX OUT”
Button Function
“DOWN”
Mounting the Fixture
On Grid:
Attach clamp tightly to yoke of fixture, according to clamp mfrs.
instructions. Hang clamp on pipe or grid and tighten the large screw
so that the clamp and fixture are securely mounted. Do not loosen
bolt attaching clamp to fixture, to position light. Attach safety cable
between the fixture and the rail for necessary security.
On Stand:
Using the 5/8" female (not included) stand fitting. Choose proper size
stand for fixture. Always use sufficient stabilizing weight on stand base.
Allows mounting the fixture on 5/8" (not included) male stand stud.
Make sure the stand is large enough to support the weight of the
fixture while maintaining good balance at the desired height. Attach
the female stand-fitting tightly to the yoke and rotate yoke so it is on
the underside of the fixture. Tighten yoke, clamp locking lever, and
place female stand-fitting over stand, making sure that its locking
screw is loosened enough to allow the fitting to completely fit over
the 5/8" stand stud. Tighten knob, making sure its screw is under the
safety cut of the stand fitting stud. Add additional weight to base of
stand for increased stability.
AN4910073 - RE
V
“A
”
11.29”
28.7 cm
17”
43.2 cm
11.22”
30.7 cm
18.46”
46.9 cm
Pole Operated
G6LED123
High-Performance StudioLED FRESNEL
®
Motorized Zoom
AC cord with POWERCON
Conector 16 ft (4.82 m)
G6CNT154