36
VIBRONET Installation 06.2016
Installation
Q:\VIBRONET\sigma\V3\VIB5 890-3_SIGNALMASTER_Standard_Package_SAP_16092015.xlsx
connect to
1X1
Power Supply
connect to
SIGNALMASTER
L
L1.1
1T1-L
1P1
VIB 5.802
V3
L1.1
1T2-L
connect to
MULTI-IO
Channel
50-pol
MS16
N
N
N
1T1-N
nc
17
A6:Hi (AD1)
RD
N
1T2-N
nc
33
A6:Lo (AD1)
BK
PE
PE
PE
nc
nc
16
A5:Hi (AD1)
RD
PE
PE-Cabinet
nc
32
A5:Lo (AD1)
BK
1X2-5V
+
1T1
TBL015-105
L
1X1-L1.1
nc
15
A4:Hi (AD1)
RD
1C1-1
-
5,08VDC
N
1X1-N
nc
31
A4:Lo (AD1)
BK
1X2-12V
+
1T2
TBL015-112
L
1X1-L1.1
nc
14
A3:Hi (AD3)
RD
1C1-3
-
12VDC
N
1X1-N
nc
30
A3:Lo (AD3)
BK
1T1-
1
5
PE-Cabinet
nc
13
A2:Hi (AD2)
RD
1X2-0V
2
6
nc
nc
29
A2:Lo (AD2)
BK
1T2-
3
7
nc
nc
12
A1:Hi (AD1)
RD
1X2-0V
4
8
nc
nc
28
A1:Lo (AD1)
BK
nc
11
OUT5
YE
1X2
Terminal Strip
nc
27
OUT6
YE
connect to
Term
Funktion
Term
connect to
nc
44
OUT7
YE
1T1+
5V
5V
nc
nc
20
OUT8
YE
1P1-4
5V
5V
nc
nc
9
P1
YE
1T2+
12V
12V
1K1-1
nc
42
P2
YE
1P1-36
12V
12V
nc
1K1-3
7
OUT1
YE
1P1-21
0V
0V
1C1-2
1K1-4
8
OUT2
YE
1P1-37
0V
0V
1C1-4
nc
40
OUT3
YE
1P1-22
0V
0V
1K1-2
nc
41
OUT4
YE
1P1-23
0V
0V
nc
nc
5
IN1
YE
1P1-24
0V
0V
nc
nc
6
IN2
YE
1P1-25
0V
0V
nc
nc
38
IN3
YE
nc
12V-Switch
12V-Switch
1P1-3
nc
39
IN4
YE
nc
10
KP/AC
YE
1K1
VIB 5.917
Relais
nc
43
SYNC
YE
connect to
Term
Funktion
Term
connect to
1X2-12V-Switch
3
12V Switch
RD
12 Vdc
1
1X2-12V
1X2-12V
36
12 V Supply
RD
PG
2
1X2-0V
1X2-5V
4
5 V Supply
RD
Sw-In 1
3
1P1-7
nc
34
PE
GN/YE
Sw-In 2
4
1P1-8
nc
35
KP/DC
YE
NO1
5
Normally Open (12)
nc
49, 50 AG
DBU
Digital-
MS12
COM1
6
Common (11)
nc
47,48 AG
DBU
OUT_1
COM1
7
Common (11)
nc
45,46 AG
DBU
NC1
8
Normally Close (14)
nc
26
PG
DBU
NO2
9
Normally Open (12)
1X2-0V
24,25 PG
DBU
Digital-
MS12
COM2
10
Common (11)
1X2-0V
22,23 PG
DBU
OUT_2
COM2
11
Common (11)
1X2-0V
21, 37 PG
DBU
NC2
12
Normally Close (14)
nc
1
LAN: TX+
BN
nc
2
LAN: TX-
RD
connect to
Eth
connect to
nc
18
LAN: RX+
OG
Ethernet
MS25/4
Tx+
1
Tx+
nc
19
LAN: RX-
BU
CAT 5.E
Tx-
2
Tx-
1P1-RJ45
nc
D-SUB RS232/1
9-pol
Rx+
3
Rx+
nc
D-SUB RS232/2
9-pol
Rx-
6
Rx-
Eth-RJ45
RJ45
Eth 100MBit
Eth. Schield
Shield
PE
1P2-SYSTEM-BUS
D-SUB SYSTEM-BUS
15-pol
nc
D-SUB EVENT-BUS
15-pol
1P2
VIB 5.815-3
SP-Modul
connect to
Term
Channel
Signal
String1
MS20 EMV
MUX-String1
TNC
String 1
MUX-String2
TNC
String 2
MUX-String3
TNC
String 3
nc
BNC
100mV/g
1P1-SYSTEM-BUS
D-SUB
SYSTEM-BUS
String2
MS20 EMV
nc
D-SUB
SPM-BUS
Shield
Shield Clamp
connect to
Term
Function
Shield-String1
max Ø8mm
String3
MS20 EMV
Shield-String2
max Ø8mm
Shield-String3
max Ø8mm
PE-Cabinet
max Ø4mm
AC Connection
PE-Cabinet
1,5mm²
PE / PA
Earth-Bolt
1X1-PE
2,5mm²
Plate
2,5mm²
Flange Plate
2,5mm²
Cabinet Door
2,5mm²
Shield-PE
2,5mm²
Fuse 6,3A
1X1 wired with (1,5mm²)
PE wired with (2,5mm³)
all other with (0,5mm²), if not
different denoted
Customer:
Project:
Date:
Editor:
AK
Cntrl. MD
Sheet No.
1/1
PRUFTECHNIK CM, (DE) 88250
Weingarten
VIB 5.890-3 SIGNALMASTER
Standard Package SAP
16.09.2015
VIBRONET Signalmaster cabinet
L1
1F1
6,3AT
100 - 240V AC
0,71 - 0,43A
50-60Hz
1C1
VIB-SO-RV
C220nF
CAT5 Terminal Box
RJ45
PE
Wiring diagram for VIBRONET Signalmaster cabinet